ArticleMicromachines2023
A Low-Noise Micromachined Accelerometer with Reconfigurable Electrodes for Resonance Suppression.
Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- A nonlinear stiffness softening mechanism for low-bias, high-sensitivity MEMS accelerometers with extended dynamic range.Microsystems & nanoengineering · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
We present a high-performance capacitive accelerometer with a sub-µg noise limit and 1.2 kHz bandwidth for particle acceleration detection applications. The low noise of the accelerometer is achieved through a combination of device design optimization and operation under vacuum to reduce the effects of air damping. Operation under vacuum, however, causes amplification of signals around the resonance region, potentially resulting in incapacitating it through saturation of interface electronics or nonlinearities and even damage. The device has thus been designed with two sets of electrodes for high and low electrostatic coupling efficiency. During normal operation, the open-loop device utilizes its high-sensitivity electrodes to provide the best resolution. When a strong signal near resonance is detected, the electrodes with low sensitivity are used for signal monitoring, while the high-sensitivity electrodes are used to apply feedback signals efficiently. A closed-loop electrostatic feedback control architecture is designed to counteract the large displacements of the proof mass near resonance frequency. Therefore, the ability to reconfigure electrodes lets the device be used in high-sensitivity or high-resiliency modes. Several experiments were conducted with DC and AC excitation at different frequencies to verify the effectiveness of the control strategy. The results showed a ten-fold reduction of displacement at resonance in the closed-loop arrangement compared to the open-loop system with a quality factor of 120.