Evidence map›Paper›PMID 33977054›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2021

MRI-Compatible and Conformal Electrocorticography Grids for Translational Research.

Florian Fallegger, Giuseppe Schiavone, Elvira Pirondini, Fabien B Wagner, Nicolas Vachicouras, Ludovic Serex, Gregory Zegarek, Adrien May, Paul Constanthin, Marie Palma and 7 more

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
4.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 57 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Review
  16. Translational Organic Neural Interface Devices at Single Neuron Resolution.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Article
  17. X-Ray Markers for Thin Film Implants.Advanced healthcare materials · 2022
    Article
  18. Article
  19. Article
  20. MRI-Compatible and Conformal Electrocorticography Grids for Translational Research.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors at 5 institutions in 3 countries.

Florian FalleggerBertarelli Foundation Chair in Neuroprosthetic Technology Laboratory for Soft Bioelectronic Interfaces Institute of Microengineering Institute of Bioengineering Center for Neuroprosthetics Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva 1202 Switzerland.ORCID 0000-0003-0626-5264
Giuseppe SchiavoneBertarelli Foundation Chair in Neuroprosthetic Technology Laboratory for Soft Bioelectronic Interfaces Institute of Microengineering Institute of Bioengineering Center for Neuroprosthetics Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva 1202 Switzerland.ORCID 0000-0001-7121-9825
Elvira PirondiniDepartment of Neurosurgery University Hospital of Lausanne (CHUV) and University of Lausanne (UNIL) Lausanne 1010 Switzerland.ORCID 0000-0002-8078-3951
Fabien B WagnerDefitech Center for Interventional Neurotherapies (NeuroRestore) Department of Neurosurgery University Hospital of Lausanne (CHUV) University of Lausanne (UNIL) Lausanne 1015 Switzerland.ORCID 0000-0002-9582-6109
Nicolas VachicourasBertarelli Foundation Chair in Neuroprosthetic Technology Laboratory for Soft Bioelectronic Interfaces Institute of Microengineering Institute of Bioengineering Center for Neuroprosthetics Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva 1202 Switzerland.ORCID 0000-0001-5073-2312
Ludovic SerexBertarelli Foundation Chair in Neuroprosthetic Technology Laboratory for Soft Bioelectronic Interfaces Institute of Microengineering Institute of Bioengineering Center for Neuroprosthetics Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva 1202 Switzerland.ORCID 0000-0002-6221-1351
Gregory ZegarekDepartment of Neurosurgery Hôpital Universitaire de Genève (HUG) Geneva 1205 Switzerland.
Adrien MayDepartment of Neurosurgery Hôpital Universitaire de Genève (HUG) Geneva 1205 Switzerland.
Paul ConstanthinDepartment of Neurosurgery Hôpital Universitaire de Genève (HUG) Geneva 1205 Switzerland.ORCID 0000-0003-1914-8876
Marie PalmaBrainTech Laboratory Inserm Univ Grenoble Alpes Grenoble 38400 France.
Mehrdad KhoshnevisBrainTech Laboratory Inserm Univ Grenoble Alpes Grenoble 38400 France.ORCID 0000-0003-0609-0898
Dirk Van RoostDepartment of Neurosurgery Hôpital Universitaire de Genève (HUG) Geneva 1205 Switzerland.ORCID 0000-0003-0224-8782
Blaise YvertBrainTech Laboratory Inserm Univ Grenoble Alpes Grenoble 38400 France.
Grégoire CourtineDefitech Center for Interventional Neurotherapies (NeuroRestore) Department of Neurosurgery University Hospital of Lausanne (CHUV) University of Lausanne (UNIL) Lausanne 1015 Switzerland.
Karl SchallerDepartment of Neurosurgery Hôpital Universitaire de Genève (HUG) Geneva 1205 Switzerland.ORCID 0000-0002-3848-0789
Jocelyne BlochDepartment of Neurosurgery University Hospital of Lausanne (CHUV) and University of Lausanne (UNIL) Lausanne 1010 Switzerland.ORCID 0000-0002-6405-1590
Stéphanie P LacourBertarelli Foundation Chair in Neuroprosthetic Technology Laboratory for Soft Bioelectronic Interfaces Institute of Microengineering Institute of Bioengineering Center for Neuroprosthetics Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva 1202 Switzerland.ORCID 0000-0001-9075-4022
École Polytechnique Fédérale de Lausanne · CHHôpital Beau-Séjour · CHUniversity Hospital of Lausanne · CHInserm · FRGhent University Hospital · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraoperative electrocorticography (ECoG) captures neural information from the surface of the cerebral cortex during surgeries such as resections for intractable epilepsy and tumors. Current clinical ECoG grids come in evenly spaced, millimeter-sized electrodes embedded in silicone rubber. Their mechanical rigidity and fixed electrode spatial resolution are common shortcomings reported by the surgical teams. Here, advances in soft neurotechnology are leveraged to manufacture conformable subdural, thin-film ECoG grids, and evaluate their suitability for translational research. Soft grids with 0.2 to 10 mm electrode pitch and diameter are embedded in 150 µm silicone membranes. The soft grids are compatible with surgical handling and can be folded to safely interface hidden cerebral surface such as the Sylvian fold in human cadaveric models. It is found that the thin-film conductor grids do not generate diagnostic-impeding imaging artefacts (<1 mm) nor adverse local heating within a standard 3T clinical magnetic resonance imaging scanner. Next, the ability of the soft grids to record subdural neural activity in minipigs acutely and two weeks postimplantation is validated. Taken together, these results suggest a promising future alternative to current stiff electrodes and may enable the future adoption of soft ECoG grids in translational research and ultimately in clinical settings.

Indexed as

Electrodes, ImplantedAnimalsBrain MappingCadaverElectrocorticographyEquipment DesignHumansMagnetic Resonance ImagingModels, AnimalNanotechnologySwineSwine, MiniatureTranslational Research, BiomedicalelectrocorticographyMRI compatibilityneural implantssoft electrodestranslational research

Identifiers

PMID33977054
PMCPMC8097365
OpenAlexW3135711454

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked