ArticleMicromachines2021
A Real-Time Circuit Phase Delay Correction System for MEMS Vibratory Gyroscopes.
Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Review of Research Advances in Gyroscopes' Structural Forms and Processing Technologies Viewed from Performance Indices.Sensors (Basel, Switzerland) · 2025Review
- Identification and correction of phase delay errors for hemispherical resonator gyroscopes.Scientific reports · 2025Article
- Range Expansion Technology for Ring MEMS Gyroscopes Based on Drive Voltage Modulation.Micromachines · 2024Article
- A Self-Oscillating Driving Circuit for Low-Q MEMS Vibratory Gyroscopes.Micromachines · 2023Article
- A Novel Packaged Ultra-High Q Silicon MEMS Butterfly Vibratory Gyroscope.Micromachines · 2022Article
- Online Compensation of Phase Delay Error Based on P-F Characteristic for MEMS Vibratory Gyroscopes.Micromachines · 2022Article
- Effect of Quadrature Control Mode on ZRO Drift of MEMS Gyroscope and Online Compensation Method.Micromachines · 2022Article
- Design, Dynamics, and Optimization of a 3-DoF Nonlinear Micro-Gyroscope by Considering the Influence of the Coriolis Force.Micromachines · 2022Article
- ZRO Drift Reduction of MEMS Gyroscopes via Internal and Packaging Stress Release.Micromachines · 2021Article
- A Novel High-Q Dual-Mass MEMS Tuning Fork Gyroscope Based on 3D Wafer-Level Packaging.Sensors (Basel, Switzerland) · 2021Article
- Real-Time Built-In Self-Test of MEMS Gyroscope Based on Quadrature Error Signal.Micromachines · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
With the development of the designing and manufacturing level for micro-electromechanical system (MEMS) gyroscopes, the control circuit system has become a key point to determine their internal performance. Nevertheless, the phase delay of electronic components may result in some serious hazards. This study described a real-time circuit phase delay correction system for MEMS vibratory gyroscopes. A detailed theoretical analysis was provided to clarify the influence of circuit phase delay on the in-phase and quadrature (IQ) coupling characteristics and the zero-rate output (ZRO) utilizing a force-to-rebalance (FTR) closed-loop detection and quadrature correction system. By deducing the relationship between the amplitude-frequency, the phase-frequency of the MEMS gyroscope, and the phase relationship of the whole control loop, a real-time correction system was proposed to automatically adjust the phase reference value of the phase-locked loop (PLL) and thus compensate for the real-time circuit phase delay. The experimental results showed that the correction system can accurately measure and compensate the circuit phase delay in real time. Furthermore, the unwanted IQ coupling can be eliminated and the ZRO was decreased by 755% to 0.095°/s. This correction system realized a small angle random walk of 0.978°/√h and a low bias instability of 9.458°/h together with a scale factor nonlinearity of 255 ppm at room temperature. The thermal drift of the ZRO was reduced to 0.0034°/s/°C at a temperature range from -20 to 70 °C.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.