Evidence map›Paper›PMID 31908452›Full record

ArticleInternational journal of nanomedicine2019

Atomic Layer Deposition Coating of TiO

Fan Yang, Run Chang, Thomas J Webster

Abstract read
In one paragraph

Article in International journal of nanomedicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Natural and long-term preservable anticoagulant property of SiOFrontiers in bioengineering and biotechnology · 2025
    Article
  5. Review
  6. Bacterial nano-factories as a tool for the biosynthesis of TiOApplied biochemistry and biotechnology · 2024
    Review
  7. Article
  8. Article
  9. Article
  10. Ultrathin TiOACS applied materials & interfaces · 2024
    Article
  11. Coatings for Cardiovascular Stents-An Up-to-Date Review.International journal of molecular sciences · 2024
    Review
  12. Research progress of absorbable stents.International journal of medical sciences · 2024
    Review
  13. Article
  14. Article
  15. Review
  16. Effect of the Nanorough Surface of TiOInternational journal of molecular sciences · 2023
    Article
  17. Article
  18. Article
  19. Article
  20. Applying Principles of Regenerative Medicine to Vascular Stent Development.Frontiers in bioengineering and biotechnology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Fan YangDepartment of Chemical Engineering, Northeastern University, Boston, MA 02115, USA.ORCID 0000-0002-4020-840X
Run ChangDepartment of Chemical Engineering, Northeastern University, Boston, MA 02115, USA.ORCID 0000-0002-1777-362X
Thomas J WebsterDepartment of Chemical Engineering, Northeastern University, Boston, MA 02115, USA.ORCID 0000-0002-2028-5969

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeA coronary stent is a well-known cardiovascular medical device implanted to resolve disorders of the circulatory system due to bloodstream narrowing. Since the implanted device interacts with surrounding biological environments, the surface properties of a typical implantable stent play a critical role in its success or failure. Endothelial cell adhesion and proliferation are fundamental criteria needed for the success of a medical device. Metallic coronary stents are commonly used as biomaterial platforms in cardiovascular implants. As a new generation of coronary stents, bioresorbable vascular scaffolds have attracted a great deal of attention among researchers and studies on bioresorbable materials (such as magnesium and zinc) remain a target for further optimization. However, additional surface modification is needed to control the biodegradation of the implant material while promoting biological reactions without the use of drug elution.

methodsHerein, precise temperature and thickness controlled atomic layer deposition (ALD) was utilized to provide a unique and conformal nanoscale TiO

resultsImpressively, results indicated that this TiO

conclusionOverall, the outcome of this in vitro study provided a promising ALD stent coating with unique nano-structural surface properties for increased endothelialization, and as a result, ALD should be further studied for numerous biomedical applications.

Indexed as

StentsAbsorbable ImplantsAlloysCell AdhesionCell ProliferationCoated Materials, BiocompatibleCoronary VesselsEndothelial CellsHumansMagnesiumMaterials TestingSurface PropertiesTemperatureTitaniumZincAlloysCoated Materials, BiocompatibleMagnesiumTitaniumtitanium dioxideZincatomic layer depositionbioresorbable vascular scaffoldcytocompatibilityendotheliummagnesiumtitanium dioxide

Identifiers

PMID31908452
PMCPMC6927589

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.