Evidence map›Paper›PMID 30400677›Full record

ArticleMicromachines2018

Design and Analysis of a High-Gain and Robust Multi-DOF Electro-thermally Actuated MEMS Gyroscope.

Muhammad Saqib, Muhammad Mubasher Saleem, Naveed Mazhar, Saif Ullah Awan, Umar Shahbaz Khan

Abstract read
In one paragraph

Article in Micromachines, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Muhammad SaqibDepartment of Electrical Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan. muhammad.saqib16@ee.ceme.edu.pk.ORCID 0000-0002-5955-4011
Muhammad Mubasher SaleemDepartment of Mechatronics Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan. mubasher.saleem@ceme.nust.edu.pk.
Naveed MazharDepartment of Electrical Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan. naveed.mazhar@ceme.edu.pk.
Saif Ullah AwanDepartment of Electrical Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan. saifullahawan@ceme.nust.edu.pk.
Umar Shahbaz KhanDepartment of Mechatronics Engineering, National University of Sciences and Technology, Islamabad 44000, Pakistan. u.shahbaz@ceme.nust.edu.pk.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents the design and analysis of a multi degree of freedom (DOF) electro-thermally actuated non-resonant MEMS gyroscope with a 3-DOF drive mode and 1-DOF sense mode system. The 3-DOF drive mode system consists of three masses coupled together using suspension beams. The 1-DOF system consists of a single mass whose motion is decoupled from the drive mode using a decoupling frame. The gyroscope is designed to be operated in the flat region between the first two resonant peaks in drive mode, thus minimizing the effect of environmental and fabrication process variations on device performance. The high gain in the flat operational region is achieved by tuning the suspension beams stiffness. A detailed analytical model, considering the dynamics of both the electro-thermal actuator and multi-mass system, is developed. A parametric optimization is carried out, considering the microfabrication process constraints of the Metal Multi-User MEMS Processes (MetalMUMPs), to achieve high gain. The stiffness of suspension beams is optimized such that the sense mode resonant frequency lies in the flat region between the first two resonant peaks in the drive mode. The results acquired through the developed analytical model are verified with the help of 3D finite element method (FEM)-based simulations. The first three resonant frequencies in the drive mode are designed to be 2.51 kHz, 3.68 kHz, and 5.77 kHz, respectively. The sense mode resonant frequency is designed to be 3.13 kHz. At an actuation voltage of 0.2 V, the dynamically amplified drive mode gain in the sense mass is obtained to be 18.6 µm. With this gain, a capacitive change of 28.11   f F and 862.13   f F is achieved corresponding to the sense mode amplitude of 0.15   μ m and 4.5   μ m at atmospheric air pressure and in a vacuum, respectively.

Indexed as

capacitive sensingelectro-thermal actuatorhigh gainMEMS gyroscopemulti-DOFnon-resonantrobustness

Identifiers

PMID30400677
PMCPMC6266985

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.