Evidence map›Paper›PMID 19110374›Full record

ArticleUltramicroscopy2009

Monte Carlo electron-trajectory simulations in bright-field and dark-field STEM: implications for tomography of thick biological sections.

A A Sousa, M F Hohmann-Marriott, G Zhang, R D Leapman

Open access · greenAbstract read
In one paragraph

Article in Ultramicroscopy, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
7.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 56 citations in OpenAlex.

  1. Damage-limited resolution for X-ray and electron microscopy of organic specimens.Acta crystallographica. Section D, Structural biology · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. The probe profile and lateral resolution of scanning transmission electron microscopy of thick specimens.Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada · 2012
    Article
  12. Electron microscopy of specimens in liquid.Nature nanotechnology · 2011
    Review
  13. Article
  14. Simulating STEM imaging of nanoparticles in micrometers-thick substrates.Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada · 2010
    Article
  15. Article
  16. Article
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

A A SousaLaboratory of Bioengineering and Physical Science, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bldg. 13, Rm. 3N17, 13 South Drive, Bethesda, MD 20892-5766, USA.
M F Hohmann-Marriott
G Zhang
R D Leapman
National Institute of Biomedical Imaging and Bioengineering · USNational Institutes of Health · US

Funding

Scanning Transmission Electron Tomography of Biological StructuresZIAEB000046 · NIBIB · NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING · PI LEAPMAN, RICHARD · 2009 to 2025
$13.0M
Electron Tomography Of Cellular StructuresZIAEB000017 · NIBIB · NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING · PI LEAPMAN, RICHARD · 2009 to 2016
$838k
Electron Tomography Of Cellular StructuresZ01EB000017 · NIBIB · NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING · PI LEAPMAN, RICHARD · 2007 to 2008
$56k
Intramural NIH HHS Z01 EB000017
6 · The paper itself

Abstract

A Monte Carlo electron-trajectory calculation has been implemented to assess the optimal detector configuration for scanning transmission electron microscopy (STEM) tomography of thick biological sections. By modeling specimens containing 2 and 3 at% osmium in a carbon matrix, it was found that for 1-microm-thick samples the bright-field (BF) and annular dark-field (ADF) signals give similar contrast and signal-to-noise ratio provided the ADF inner angle and BF outer angle are chosen optimally. Spatial resolution in STEM imaging of thick sections is compromised by multiple elastic scattering which results in a spread of scattering angles and thus a spread in lateral distances of the electrons leaving the bottom surface. However, the simulations reveal that a large fraction of these multiply scattered electrons are excluded from the BF detector, which results in higher spatial resolution in BF than in high-angle ADF images for objects situated towards the bottom of the sample. The calculations imply that STEM electron tomography of thick sections should be performed using a BF rather than an ADF detector. This advantage was verified by recording simultaneous BF and high-angle ADF STEM tomographic tilt series from a stained 600-nm-thick section of C. elegans. It was found that loss of spatial resolution occurred markedly at the bottom surface of the specimen in the ADF STEM but significantly less in the BF STEM tomographic reconstruction. Our results indicate that it might be feasible to use BF STEM tomography to determine the 3D structure of whole eukaryotic microorganisms prepared by freeze-substitution, embedding, and sectioning.

Indexed as

Monte Carlo MethodAnimalsCaenorhabditis elegansComputer SimulationElectron Microscope Tomography

Identifiers

PMID19110374
PMCPMC2705993
OpenAlexW1986901576

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.