Evidence map›Paper›PMID 9916923›Full record

ArticleThe American journal of pathology1999

Rapid simultaneous amplification and detection of the MBR/JH chromosomal translocation by fluorescence melting curve analysis.

S D Bohling, T C King, C T Wittwer, K S Elenitoba-Johnson

Open access · greenAbstract readComment
In one paragraph

Article in The American journal of pathology, 1999. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 26 citations in OpenAlex.

  1. Doubling Throughput of a Real-Time PCR.Scientific reports · 2015
    Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

S D BohlingDepartment of Pathology, University of Utah Health Sciences Center and ARUP Institute for Clinical and Experimental Pathology, Salt Lake City 84132, USA.
T C King
C T Wittwer
K S Elenitoba-Johnson
ARUP Institute for Clinical and Experimental PathologyRoger Williams Medical Center · USUniversity of Utah · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Polymerase chain reaction (PCR) amplification and product analysis for the detection of chromosomal translocations, such as the t(14;18), has traditionally been a two-step process. PCR product detection has generally entailed gel electrophoresis and/or hybridization or sequencing for confirmation of assay specificity. Using a microvolume fluorimeter integrated with a thermal cycler and a PCR-compatible double-stranded DNA (dsDNA) binding fluorescent dye (SYBR Green I), we investigated the feasibility of simultaneous thermal amplification and detection of MBR/JH translocation products by fluorescence melting curve analysis. We analyzed DNA from 30 cases of lymphoproliferative disorders comprising 19 cases of previously documented MBR/JH-positive follicle center lymphoma and 11 reactive lymphadenopathies. The samples were coded and analyzed blindly for the presence of MBR/JH translocations by fluorescence melting curve analysis. We also performed dilutional assays using the MBR/JH-positive cell line SUDHL-6. Multiplex PCR for MBR/JH and beta-globin was used to simultaneously assess sample adequacy. All (100%) of the 19 cases previously determined to be MBR/JH positive by conventional PCR analysis showed a characteristic sharp decrease in fluorescence at approximately 90 degrees C by melting curve analysis after amplification. Fluorescence melting peaks obtained by plotting the negative derivative of fluorescence over temperature (-dF/dT) versus temperature (T) showed melting temperatures (Tm) at 88.85+/-1.15 degrees C. In addition, multiplex assays using both MBR/JH and beta-globin primers yielded easily distinguishable fluorescence melting peaks at approximately 90 degrees C and 81.2 degrees C, respectively. Dilutional assays revealed that fluorescence melting curve analysis was more sensitive than conventional PCR and agarose gel electrophoresis with ultraviolet transillumination by as much as 100-fold. Simultaneous amplification and fluorescence melting curve analysis is a simple, reliable, and sensitive method for the detection of MBR/JH translocations. The feasibility of specific PCR product detection without electrophoresis or utilization of expensive fluorescently labeled probes makes this method attractive for routine molecular diagnostics.

Indexed as

Chromosome MappingDNA, ViralFeasibility StudiesFluorometryGlobinsHerpesvirus 4, HumanHot TemperatureHumansImmunoglobulin Joining RegionLymphoproliferative DisordersPolymerase Chain ReactionTime FactorsTranslocation, GeneticDNA, ViralGlobinsImmunoglobulin Joining Region

Identifiers

PMID9916923
PMCPMC1853425
OpenAlexW2005049967

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked