Evidence map›Paper›PMID 9675208›Full record

ArticleBiophysical journal1998

Optical recording system based on a fiber optic image conduit: assessment of microscopic activation patterns in cardiac tissue.

S Rohr, J P Kucera

Abstract read
In one paragraph

Article in Biophysical journal, 1998. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Optical mapping of contracting hearts.The Journal of physiology · 2023
    Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Cell cultures as models of cardiac mechanoelectric feedback.Progress in biophysics and molecular biology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

S RohrDepartment of Physiology, University of Bern, CH-3012 Bern, Switzerland.rohr@pyl.unibe.ch
J P Kucera

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical recording of transmembrane voltage changes with the use of potentiometric dyes has opened the possibility of determining spatial patterns of electrical activity in excitable tissues. To follow such activation patterns on the cellular/subcellular level in heart cell cultures, a recording system was developed that features both high spatial resolution (4-200 microm) and high temporal resolution (uncertainty in the determination of delays between fast rising signals of +/-1 micros). Central to the system is a fiber optic image conduit consisting of 379 individual optical fibers. At one end the fibers are fused to form an input window that matches the size of the field of view of the microscope. At the other end, the fibers are loose, permitting a selectable subset to be connected to 80 discrete photodetectors. This design allows the sensitive area of the imager to be adapted to regions of interest in a given preparation, thus making optimal use of the limited number of detectors. Furthermore, by using a second fiber optic imager, individual photodetectors can be assigned to different optical ports, thus providing the means for fast and simultaneous dual-emission wavelength measurements. This feature permitted the elimination of motion artifacts arising from the myocytes without the use of contraction-suppressing drugs.

Indexed as

Action PotentialsAnimalsAnimals, NewbornCell DivisionCells, CulturedElectronicsEquipment DesignFiber Optic TechnologyHeartHeart VentriclesMicroscopy, FluorescenceMyocardiumOptical FibersRatsReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID9675208
PMCPMC1299781

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.