Evidence map›Paper›PMID 9370477›Full record

ArticleBiophysical journal1997

Mapping fluorophore distributions in three dimensions by quantitative multiple angle-total internal reflection fluorescence microscopy.

B P Olveczky, N Periasamy, A S Verkman

Abstract read
In one paragraph

Article in Biophysical journal, 1997. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Methods to Measure Water Permeability.Advances in experimental medicine and biology · 2023
    Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Axial superresolution via multiangle TIRF microscopy with sequential imaging and photobleaching.Proceedings of the National Academy of Sciences of the United States of America · 2016
    Article
  13. Selectable Surface and Bulk Fluorescence Imaging with Plasmon-Coupled Waveguides.The journal of physical chemistry. C, Nanomaterials and interfaces · 2015
    Article
  14. Review
  15. Fast high-resolution 3D total internal reflection fluorescence microscopy by incidence angle scanning and azimuthal averaging.Proceedings of the National Academy of Sciences of the United States of America · 2014
    Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

B P OlveczkyDepartment of Medicine, Cardiovascular Research Institute, University of California, San Francisco 94143, USA.
N Periasamy
A S Verkman

Funding

APPLICATION OF NOVEL OPTICAL METHODS TO CELL DYNAMICSR01DK043840 · NIDDK · UNIVERSITY OF CALIFORNIA SAN FRANCISCO · PI VERKMAN, ALAN S · 1993 to 2001
$494k
ROLE OF THE MEMBRANE SKELETON IN PATHOLOGIC RED CELLSR01DK016095 · NIDDK · UNIVERSITY OF CALIFORNIA SAN FRANCISCO · PI SHOHET, STEPHEN B · 1986 to 2000
$230k
MECHANISMS OF WATER TRANSPORT IN RENAL EPITHELIAR03TW000704 · FIC · UNIVERSITY OF CALIFORNIA SAN FRANCISCO · PI VERKMAN, ALAN S · 1996 to 1998
–
FIC NIH HHS TW00704NIDDK NIH HHS DK16095NIDDK NIH HHS DK43840
6 · The paper itself

Abstract

The decay of evanescent field intensity beyond a dielectric interface depends upon beam incident angle, enabling the 3-d distribution of fluorophores to be deduced from total internal reflection fluorescence microscopy (TIRFM) images obtained at multiple incident angles. Instrumentation was constructed for computer-automated multiple angle-TIRFM (MA-TIRFM) using a right angle F2 glass prism (n(r) 1.632) to create the dielectric interface. A laser beam (488 nm) was attenuated by an acoustooptic modulator and directed onto a specified spot on the prism surface. Beam incident angle was set using three microstepper motors controlling two rotatable mirrors and a rotatable optical flat. TIRFM images were acquired by a cooled CCD camera in approximately 0.5 degree steps for >15 incident angles starting from the critical angle. For cell studies, cells were grown directly on the glass prisms (without refractive index-matching fluid) and positioned in the optical path. Images of the samples were acquired at multiple angles, and corrected for angle-dependent evanescent field intensity using "reference" images acquired with a fluorophore solution replacing the sample. A theory was developed to compute fluorophore z-distribution by inverse Laplace transform of angle-resolved intensity functions. The theory included analysis of multiple layers of different refractive index for cell studies, and the anisotropic emission from fluorophores near a dielectric interface. Instrument performance was validated by mapping the thickness of a film of dihexyloxacarbocyanine in DMSO/water (n(r) 1.463) between the F2 glass prism and a plano-convex silica lens (458 mm radius, n(r) 1.463); the MA-TIRFM map accurately reproduced the lens spherical surface. MA-TIRFM was used to compare with nanometer z-resolution the geometry of cell-substrate contact for BCECF-labeled 3T3 fibroblasts versus MDCK epithelial cells. These studies establish MA-TIRFM for measurement of submicroscopic distances between fluorescent probes and cell membranes.

Indexed as

Microscopy, Fluorescence3T3 CellsAnimalsAnisotropyCarbocyaninesCell LineCell MembraneDogsFluoresceinsFluorescent DyesKidneyLasersMathematicsMiceRefractometry2',7'-bis(carboxyethyl)-5(6)-carboxyfluorescein3,3'-dihexyl-2,2'-oxacarbocyanineCarbocyaninesFluoresceinsFluorescent Dyes

Identifiers

PMID9370477
PMCPMC1181185

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.