Evidence map›Paper›PMID 9144380›Full record

ArticleClinical and diagnostic laboratory immunology1997

Standardization of measurement of immunoglobulin-secreting cells in human peripheral circulation.

S Baqar, A A Nour El Din, D A Scott, A L Bourgeois, A S Mourad, M T Kleinosky, M J Oplinger, J R Murphy

Registry-linked trialOpen access · greenAbstract read
In one paragraph

Article in Clinical and diagnostic laboratory immunology, 1997. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT00371241 (Antibody Secreting Cell), which is not on this map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact, top 86% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT00371241 completednot on this mapstarted 2006, after this paper: background citation

Antibody Secreting Cell (ASC) and Immunoactive Protein Profiles in Neonates on Extracorporeal Membrane Oxygenation (ECMO)

TypeobservationalSponsorThe University of Texas Health Science Center, HoustonRan2006 to 2007Enrolled12ConditionsPersistent Fetal Circulation Syndrome, Diaphragmatic Hernia, Meconium Aspiration, Sepsis
3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Article
  5. Immunology of gut mucosal vaccines.Immunological reviews · 2011
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

S BaqarDepartment of Infectious Diseases, Naval Medical Research Institute, Bethesda, Maryland, USA.
A A Nour El Din
D A Scott
A L Bourgeois
A S Mourad
M T Kleinosky
M J Oplinger
J R Murphy
Naval Medical Research Command · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A sensitive, and at times the most sensitive, measurement of human vaccine immunogenicity is enumeration of antibody-secreting cells (ASC) in peripheral blood. However, this assay, which is inherently capable of measurement of the absolute number of antigen-specific ASC, is not standardized. Thus, quantitative comparison of results between laboratories is not currently possible. To address this issue, isotype-specific ASC were enumerated from paired fresh and cryopreserved mononuclear cell (MNC) preparations from healthy adult volunteers resident in either the United States (US group) or Egypt (EG group). Analysis of fresh cells from US volunteers revealed mean numbers of ASC per 10(6) MNC of 617, 7,738, and 868 for immunoglobulin M (IgM), IgG, and IgA, respectively, whereas EG volunteers had 2,086, 7,580, and 1,677 ASC/10(6) MNC for the respective isotypes. Cryopreservation resulted in a slight reduction in group mean IgM, IgG, and IgA ASC (maximum reduction in group mean, 14%), but in no instance were results obtained with cryopreserved cells significantly lower than those obtained with fresh cells. To determine if cryopreservation affected the number of bacterial antigen-specific ASC detected, cells from a group of US adult volunteers who received a single oral dose of a mutated Escherichia coli heat-labile enterotoxin (LT(R192G)) were tested. There was no significant difference (P > 0.05) in the number of antigen-specific IgA or IgG ASC detected between fresh and cryopreserved MNC. The results support the views that ASC assays can be standardized to yield quantitative results and that the methodology can be changed to make the test more practical.

Indexed as

Escherichia coli ProteinsAdultAntibodies, BacterialAntibody-Producing CellsAntigens, BacterialBacterial ToxinsBlood PreservationCryopreservationEnterotoxinsEscherichia coliFemaleHumansImmunoglobulin IsotypesImmunoglobulinsLymphocyte CountMaleAntibodies, BacterialAntigens, BacterialBacterial ToxinsEnterotoxinsEscherichia coli Proteinsheat-labile enterotoxin, E coliImmunoglobulin IsotypesImmunoglobulins

Identifiers

PMID9144380
PMCPMC170535
OpenAlexW2120060974

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.