Evidence map›Paper›PMID 8770215›Full record

ArticleBiophysical journal1996

Multiple- and single-molecule analysis of the actomyosin motor by nanometer-piconewton manipulation with a microneedle: unitary steps and forces.

A Ishijima, H Kojima, H Higuchi, Y Harada, T Funatsu, T Yanagida

Abstract read
In one paragraph

Article in Biophysical journal, 1996. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 74 papers.

0numbers the graph read from it
0cells of the map it votes in
74citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

74 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Nanopore Technology for the Application of Protein Detection.Nanomaterials (Basel, Switzerland) · 2021
    Review
  12. A reverse stroke characterizes the force generation of cardiac myofilaments, leading to an understanding of heart function.Proceedings of the National Academy of Sciences of the United States of America · 2021
    Article
  13. A Myosin II-Based Nanomachine Devised for the Study of CaInternational journal of molecular sciences · 2020
    Article
  14. Probing Changes in CaMicromachines · 2020
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

14 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

A IshijimaBio-Motron Project, ERATO, JRDC, Osaka, Japan. ishijima@yanagida.jrdc.go.jp
H Kojima
H Higuchi
Y Harada
T Funatsu
T Yanagida

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have developed a new technique for measurements of piconewton forces and nanometer displacements in the millisecond time range caused by actin-myosin interaction in vitro by manipulating single actin filaments with a glass microneedle. Here, we describe in full the details of this method. Using this method, the elementary events in energy transduction by the actomyosin motor, driven by ATP hydrolysis, were directly recorded from multiple and single molecules. We found that not only the velocity but also the force greatly depended on the orientations of myosin relative to the actin filament axis. Therefore, to avoid the effects of random orientation of myosin and association of myosin with an artificial substrate in the surface motility assay, we measured forces and displacements by myosin molecules correctly oriented in single synthetic myosin rod cofilaments. At a high myosin-to-rod ratio, large force fluctuations were observed when the actin filament interacted in the correct orientation with a cofilament. The noise analysis of the force fluctuations caused by a small number of heads showed that the myosin head generated a force of 5.9 +/- 0.8 pN at peak and 2.1 +/- 0.4 pN on average over the whole ATPase cycle. The rate constants for transitions into (k+) and out of (k-) the force generation state and the duty ratio were 12 +/- 2 s-1, and 22 +/- 4 s-1, and 0.36 +/- 0.07, respectively. The stiffness was 0.14 pN nm-1 head-1 for slow length change (100 Hz), which would be approximately 0.28 pN nm-1 head-1 for rapid length change or in rigor. At a very low myosin-to-rod ratio, distinct actomyosin attachment, force generation (the power stroke), and detachment events were directly detected. At high load, one power stroke generated a force spike with a peak value of 5-6 pN and a duration of 50 ms (k(-)-1), which were compatible with those of individual myosin heads deduced from the force fluctuations. As the load was reduced, the force of the power stroke decreased and the needle displacement increased. At near zero load, the mean size of single displacement spikes, i.e., the unitary steps caused by correctly oriented myosin, which were corrected for the stiffness of the needle-to-myosin linkage and the randomizing effect by the thermal vibration of the needle, was approximately 20 nm.

Indexed as

ActomyosinAnimalsBiophysicsEnergy MetabolismIn Vitro TechniquesMicroscopy, ElectronModels, BiologicalMovementMuscle ContractionMuscle Fibers, SkeletalMuscle, SkeletalMyosinsRabbitsActomyosinMyosins

Identifiers

PMID8770215
PMCPMC1224937

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.