Evidence map›Paper›PMID 8735095›Full record

ArticleJournal of clinical microbiology1996

Quantitative detection of human immunodeficiency virus (HIV) antigen by the Enzymun-Test: comparison with alternative assays and nucleic acid sequence-based amplification of HIV type 1 RNA.

B Weber, W Melchior, W Preiser, G Hess, M Wahl, J Braner, H W Doerr

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Journal of clinical microbiology, 1996. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

B WeberInstitut für Medizinische Virologie, Zentrum der Hygiene, Universitätskliniken Frankfurt am Main, Germany.
W Melchior
W Preiser
G Hess
M Wahl
J Braner
H W Doerr
Institut für Hygiene und Umwelt · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A new modular automated enzyme immunoassay (EIA) (Enzymun-Test HIV Ag: Boehringer Mannheim) for quantitative human immunodeficiency virus (HIV) antigen detection was evaluated by testing a panel of 1,506 serum samples, including seroconversions, dilution series, follow-up samples from patients under antiretroviral therapy, single serum specimens from HIV-seropositive individuals in different stages of infection, potentially cross-reactive samples, and sera from HIV-negative hospitalized patients. The Abbott HIV type 1 (HIV-1) antigen monoclonal antibody assay served as the reference assay, and nucleic acid sequence-based amplification (Organon Teknika) for quantitative amplification of HIV-1 RNA was used for follow-up of patients under antiretroviral chemotherapy. The Boehringer Mannheim and Abbott EIAs showed concordant results for the early detection of HIV antigen in all the seroconversion panels. The follow-up samples from 29 HIV-infected individuals under antiretroviral therapy gave divergent results between both antigen tests. For the detection of HIV antigen in single serum samples from HIV-infected patients in different stages of HIV infection, a higher number of positive samples was detected with the Abbott HIV-1 antigen monoclonal antibody assay in samples from patients in stages II and III of HIV infection. The Enzymun-Test detected three or more positive samples than did the Abbott assay among the samples of patients with AIDS. The concordance on a sample-to-sample basis between the Boehringer Mannheim and Abbott EIAs was 98.6%. The sensitivity of the Enzymun-Test in comparison to the reference assay was 97.2%; the specificity was 98.8%. Although no close correlation could be found between the amount of viral RNA in serum detected by nucleic acid sequence-based amplification and the concentration of HIV antigen, a high HIV-1 RNA copy number was mostly associated with high levels of HIV antigen. In conclusion, the Enzymun-Test permits accurate HIV antigen detection and offers, in contrast to previous assays, the possibility of completely automated detection.

Indexed as

Immunoenzyme TechniquesAIDS SerodiagnosisAntibodies, MonoclonalAntiviral AgentsEvaluation Studies as TopicFalse Positive ReactionsGene AmplificationHIV-1HIV AntigensHIV InfectionsHIV SeropositivityHumansRNA, ViralSensitivity and SpecificityVirologyAntibodies, MonoclonalAntiviral AgentsHIV AntigensRNA, Viral

Identifiers

PMID8735095
PMCPMC229039
OpenAlexW2134258209

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.