ArticleBiophysical journal1994
Saturation effects in polarized fluorescence photobleaching recovery and steady state fluorescence polarization.
Article in Biophysical journal, 1994. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 13 citations in OpenAlex.
- Polarized fluorescence depletion reports orientation distribution and rotational dynamics of muscle cross-bridges.Biophysical journal · 2002Article
- The orientation of eosin-5-maleimide on human erythrocyte band 3 measured by fluorescence polarization microscopy.Biophysical journal · 1996Article
- Three-photon induced fluorescence of the calcium probe Indo-1.Biophysical journal · 1996Article
- Myosin head rotation in muscle fibers measured using polarized fluorescence photobleaching recovery.Journal of fluorescence · 1995Article
- Light Quenching of Fluorescence Using Time-Delayed Laser Pulses As Observed by Frequency-Domain Fluorometry.The Journal of physical chemistry · 1994Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
The time-resolved anisotropy produced in polarized fluorescence photobleaching recovery experiments has been successfully used to measure rotational correlation times in a variety of biological systems, however the magnitudes of the reported initial anisotropies have been much lower than the theoretically predicted maximum values. This small time-zero anisotropy has been attributed to fluorophore motion, wobble and rotation, during the photobleaching pulse. We demonstrate that inclusion of the possibility of saturation of the fluorophore's transition from its ground state to its excited state during the photobleaching pulse leads to the prediction of reduced time-zero anisotropy. This eliminates the need to rely solely on the assumption of fluorophore motion during the photobleaching pulse as the cause of the reduced initial anisotropy. We present theoretical and experimental results which show that the initial anisotropy decreases as both the bleach pulse intensity is increased and bleach pulse duration is decreased so as to keep the total integrated bleach pulse constant. We also show theoretical and experimental results demonstrating that at high excitation intensity the effects of saturation cause the steady state fluorescence polarization to decrease. We estimate that saturation may occur using common photobleaching conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.