Evidence map›Paper›PMID 7926347›Full record

Trial reportDiabetologia1994

Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man.

D Moatti-Sirat, V Poitout, V Thomé, M N Gangnerau, Y Zhang, Y Hu, G S Wilson, F Lemonnier, J C Klein, G Reach

Open access · bronzeAbstract readClinical TrialComparative Study
PubMed Publisher
In one paragraph

Trial report in Diabetologia, 1994. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.7field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 49 citations in OpenAlex.

  1. Biocompatibility of common implantable sensor materials in a tumor xenograft model.Journal of biomedical materials research. Part B, Applied biomaterials · 2019
    Article
  2. Article
  3. Detection of 1,5-Anhydroglucitol by Electrochemical Impedance Spectroscopy.Journal of diabetes science and technology · 2014
    Article
  4. Article
  5. Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes.ECS journal of solid state science and technology : JSS
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

D Moatti-SiratINSERM U341, Service de Diabétologie, Hôtel-Dieu, Paris, France.
V Poitout
V Thomé
M N Gangnerau
Y Zhang
Y Hu
G S Wilson
F Lemonnier
J C Klein
G Reach
Inserm · FRUniversity of Kansas · USÉcole Nationale Supérieure des Mines de Paris · FRHôtel-Dieu de Paris · FR

Funding

STUDIES OF POTENTIALLY IMPLANTABLE GLUCOSE SENSORSR01DK030718 · NIDDK · UNIVERSITY OF KANSAS LAWRENCE · PI WILSON, GEORGE S · 1986 to 1998
–
NIDDK NIH HHS DK 30718
6 · The paper itself

Abstract

Amperometric glucose sensors typically monitor the production of hydrogen peroxide generated in the course of the enzymatic oxidation of glucose. At the applied potential necessary to oxidize the peroxide produced, other species are also electroactive and contribute to the signal. Interference of ascorbate or urate has been effectively eliminated, but that resulting from the widely used analgesic acetaminophen is not. The aim of this work was to reduce this interference, which was found to be possible by introducing a membrane constructed of Nafion. We compared the in vitro sensitivity to acetaminophen of five Nafion sensors with that of five non-Nafion sensors with identical glucose sensitivity (2.0 +/- 0.4 vs 1.9 +/- 0.1 nA.mmol-1.l-1, NS): sensitivity to acetaminophen was 12.2 +/- 2.7 vs 30.8 +/- 6.3 nA.mmol-1.l-1, respectively (p < 0.05). These sensors were tested in rats by implanting in each animal one Nafion and one non-Nafion sensors. The in vivo sensitivity to glucose was similar (0.33 +/- 0.09 vs 0.30 +/- 0.05 nA.mmol-1.l-1, NS). The current generated by an acetaminophen infusion (plasma acetaminophen plateau = 140 +/- 10 mumol/l) was much decreased in the case of the Nafion sensor: 0.5 +/- 0.3 vs 2.0 +/- 0.7 nA, p < 0.05). Five Nafion sensors were implanted in the subcutaneous tissue of normal human volunteers who were given on oral dose of 500 mg acetaminophen.(ABSTRACT TRUNCATED AT 250 WORDS)

Indexed as

Biosensing TechniquesFluorocarbon PolymersMembranes, ArtificialAcetaminophenAdultAnimalsBlood GlucoseBlood Glucose Self-MonitoringEnzymes, ImmobilizedFemaleGlucose OxidaseHumansMaleRatsRats, WistarSensitivity and SpecificityAcetaminophenBlood GlucoseEnzymes, ImmobilizedFluorocarbon PolymersGlucose OxidaseMembranes, Artificialperfluorosulfonic acid

Identifiers

PMID7926347
OpenAlexW2018378969

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.