ArticleACS omega2026
Surfactant-Assisted Colorimetric Signal Enhancement in Paper-Based Glucose Sensing.
Article in ACS omega, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Paper-based colorimetric sensors offer a low cost and accessible platform for point-of-care (POC) analysis, but enzyme activity loss during coating and drying can weaken analytical signals and require high enzyme loadings or complex immobilization procedures. Although surfactants are widely used to improve wettability in paper-based assays, their potential contribution to colorimetric performance beyond these effects remains unclear. Here, we investigated surfactant-assisted colorimetric signal enhancement in a glucose assay implemented on a 96-puddle paper plate (96-PPP) and identified Tween 20 as the most effective surfactant. Its effect on detection performance became more pronounced as glucose oxidase (GOx) loading decreased; at 0.1 mg/mL GOx, Tween 20 lowered the limit of detection (LoD) from 0.113 to 0.034 mg/mL (approximately 3.3-fold) over a working range of 0-5 mg/mL, despite no statistically significant change in the measured contact angle at this loading. Tween 20 had no appreciable effect on the reaction in solution but preserved 95% of the apparent reaction rate constant after drying, compared with 11% without it, and atomic force microscopy (AFM) revealed a more dispersed dried enzyme morphology on mica. Tween 20-containing sensors also showed slower signal decay during repeated wetting-drying cycles and thermal stress, retained 77% (vs 26%) of the response at 400 mM NaCl, and exhibited within-PPP and between-batch coefficients of variation (CVs) below 10% (vs 12.3-19.5%), while maintaining glucose selectivity over potentially interfering molecules. These results indicate that Tween 20 enhances paper-based glucose sensing through mechanisms beyond simple wettability effects, in part by retaining enzyme cascade activity during drying, although the contributions of the individual enzymes and the underlying mechanism remain to be established.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.