Evidence map›Paper›PMID 42920006›Full record

ArticleSurgical endoscopy2026

Automated triage of non-informative frames in minimally invasive surgical videos: a comparative study of domain-specific vision transformers versus general-purpose multimodal models.

Peilin Li, Juanjuan Li, Kaihong Han, Shaonan Xie, Maogang Gao, Qingyi Liu

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Peilin LiDepartment of Thoracic Surgery, The Fourth Hospital of Hebei Medical University, No. 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China.
Juanjuan LiDepartment of Ultrasound, The Fourth Hospital of Hebei Medical University, No. 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China.
Kaihong HanDepartment of Thoracic Surgery, The Fourth Hospital of Hebei Medical University, No. 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China.
Shaonan XieDepartment of Thoracic Surgery, The Fourth Hospital of Hebei Medical University, No. 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China.
Maogang GaoDepartment of Thoracic Surgery, The Fourth Hospital of Hebei Medical University, No. 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China. 592038981@qq.com.
Qingyi LiuDepartment of Thoracic Surgery, The Fourth Hospital of Hebei Medical University, No. 12 Jiankang Road, Shijiazhuang, 050011, Hebei, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMinimally invasive surgery (MIS) videos support education and quality review, but raw recordings contain non-informative frames that impede review and increase storage.

methodsWe retrospectively analyzed 300,832 frames from 120 MIS videos performed by 30 surgeons. An EndoViT-initialized Vision Transformer (ViT) was evaluated using leave-six-surgeons-out cross-validation and compared with conventional vision models. GPT-4o-mini, LLaVA, and Doubao were separately evaluated under zero- and few-shot prompting on a balanced 400-frame subset that was not sample-size matched to the ViT evaluation. We also explored the association between surgeon experience and non-informative-frame ratio.

resultsIn the within-dataset comparison of trained vision models, the EndoViT-initialized ViT achieved an aggregate accuracy and F1-score of 0.942. In an exploratory few-shot analysis within a separate 400-frame balanced benchmark, GPT-4o-mini achieved an accuracy of 0.890 and F1-score of 0.880; exemplar-test disjointness could not be confirmed. Because the ViT and LMM evaluations used different test sets and sample sizes, these estimates do not support a direct comparison of model superiority. The surgeon-level analysis showed no statistically significant association between experience and the non-informative-frame ratio (r = - 0.421, 95% CI - 0.83 to 0.28; p = 0.226).

conclusionThe EndoViT-initialized ViT performed well in this single-institution dataset, whereas prompt-only LMM performance varied in a separate small benchmark. Matched evaluation with documented exemplar-test separation and external validation is required before determining relative performance or clinical readiness. Automated frame triage may support MIS video management with human oversight.

Indexed as

Artificial intelligenceEndoViTLarge multimodal modelMinimally invasive surgeryNon-informative frame detectionSurgical video analysisVision transformer

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.