Evidence map›Paper›PMID 42918937›Full record

ArticleInternational journal of implant dentistry2026

Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible - a paired in vitro method-comparison study.

Georg Hoene, Shabnam Shahpasand, Felix Karl Waffenschmidt, Frederik Holdorf, Robert Stünkel, Alexander-Nicolai Zeller, Philipp Kauffmann

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in International journal of implant dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Georg Hoene *Clinic for Oral and Maxillofacial Surgery, University Medical Center Goettingen, Robert-Koch-Strasse 40, D-37075, Goettingen, Germany. Georg.Hoene@med.uni-goettingen.de.ORCID http://orcid.org/0000-0003-1025-6758
Shabnam Shahpasand *Department of Phoniatrics and Pediatric Audiology, University Hospital Muenster, Muenster, Germany.
Felix Karl WaffenschmidtClinic for Oral and Maxillofacial Surgery, University Medical Center Goettingen, Robert-Koch-Strasse 40, D-37075, Goettingen, Germany.
Frederik HoldorfClinic for Oral and Maxillofacial Surgery, University Medical Center Goettingen, Robert-Koch-Strasse 40, D-37075, Goettingen, Germany.
Robert StünkelDental Practice, Hildesheim, Germany.
Alexander-Nicolai ZellerDental Practice, Aachen, Germany.
Philipp KauffmannClinic for Oral and Maxillofacial Surgery, University Medical Center Goettingen, Robert-Koch-Strasse 40, D-37075, Goettingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThree-dimensional postoperative implant assessment is increasingly performed using intraoral scan (IOS) superimposition as a radiation-free alternative to cone-beam computed tomography (CBCT). However, it remains unclear to what extent IOS- and CBCT-based measurements agree and how reproducibility changes across posterior mandibular configurations.

methodsIn this paired in vitro method-comparison study, based on the experimental platform of a previous study, 60 implants placed at Fédération Dentaire Internationale (FDI) positions 35, 36, 45, 46 and 47 in bounded edentulous spaces (BES) and distal extension situations (DE) underwent three IOS-based and three CBCT-based postoperative assessments relative to the virtual plan using the Treatment Evaluation Tool of the planning software. Angular, mesiodistal, buccolingual, apico-coronal, and three-dimensional (3D) deviations at implant base and apex were recorded, resulting in 180 paired measurements. Agreement was assessed by Bland-Altman analysis, and within-method reproducibility by the within-implant standard deviation (Sw). IOS variability was additionally separated into within-scan and between-scan components. Non-parametric analyses were used for comparisons by indication and FDI position.

resultsMean absolute IOS-CBCT differences were 0.73° ± 0.55° for angular deviation, 0.22 ± 0.20 mm for the 3D base offset and 0.26 ± 0.22 mm for the 3D apical offset. Bland-Altman bias (CBCT - IOS) was small (- 0.35°; -0.05 mm; -0.07 mm) with 95% limits of agreement of [- 2.01°; +1.31°], [- 0.62; +0.53] mm and [- 0.73; +0.58] mm. Within-method reproducibility was superior for IOS in 8 of 9 parameters (e.g., Sw 0.20° vs. 0.55° for the angle), and IOS variability was dominated by scan-to-scan rather than within-scan re-evaluation. Discrepancies were larger in DE than in BES sites in 7 of 9 parameters (all p < 0.001 for the principal apical and buccolingual components) and were larger at position 47 than at position 35 (3D base p = 0.004; 3D apex p = 0.011).

conclusionsIn this in vitro setting, IOS- and CBCT-based implant assessment in the posterior mandible showed good agreement with small overall differences, and IOS demonstrated lower within-method variability than CBCT. IOS-based superimposition may therefore serve as a radiation-free complement to CBCT for the postoperative evaluation of single implants in bounded posterior sites. Agreement decreased in distal extension situations and at more distal positions; in these configurations, and whenever clinical decisions depend on sub-millimeter or sub-degree precision, CBCT remains the reference technique. Confirmation in vivo is required before routine clinical use.

Indexed as

Cone-Beam Computed TomographyDental Implantation, EndosseousDental ImplantsImaging, Three-DimensionalMandibleHumansIn Vitro TechniquesReproducibility of ResultsDental ImplantsBland-Altman analysisCone-beam computed tomographyDigital workflowImplant position accuracyIntraoral scannerIn vitro study

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.