Evidence map›Paper›PMID 42910000›Full record

ArticleArthroplasty today2026

Fluoroscopy Computer Navigation Versus Manual Fluoroscopic Acetabular Positioning in Direct Anterior Total Hip Arthroplasty: Safe Zone Compliance and Learning Curve Analysis.

Karlos E Zepeda, Carmelo Burgio, Shrey Vachhani, Tsion Yared, Edward Grabov, Jonathan M Vigdorchik, Eytan M Debbi

Abstract read
In one paragraph

Article in Arthroplasty today, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Karlos E ZepedaAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Carmelo BurgioAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Shrey VachhaniAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Tsion YaredAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Edward GrabovAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Jonathan M VigdorchikAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Eytan M DebbiAdult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Fluoroscopy is commonly leveraged in direct anterior approach total hip arthroplasty (DAA-THA). Computer-navigation systems provide real-time guidance aiming to enhance component positioning, but their learning curves and component accuracy remains incompletely characterized. This study evaluated the learning curve and safe zone compliance after implementation of computer navigation in DAA-THA. Methods: This retrospective cohort study analyzed 200 consecutive primary DAA-THA cases performed by a single high-volume surgeon: 100 manual and 100 computer-navigated cases using the Velys Hip Navigation system. Acetabular component inclination and anteversion were measured on postoperative standing radiographs. Safe zone compliance was assessed using surgeon-defined, Lewinnek, and Callanan criteria. Learning curve analysis utilized segmented linear regression and cumulative sum methods. Operative time, fluoroscopy exposure, and component safe zone compliance were compared between groups. Results: Operative time stabilized after 6 cases ( Conclusions: Fluoroscopic based computer navigation was associated with higher safe zone compliance in DAA-THA with a rapid 6-case learning curve and reduced operative time, without increasing radiation exposure.

Indexed as

Acetabular componentDirect anterior approachFluoroscopyLearning curveNavigationTotal hip arthroplasty

Identifiers

PMID42910000
PMCPMC13686042

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked