Evidence map›Paper›PMID 42909613›Full record

ArticlePediatric cardiology2026

Aorto-Pulmonary Shunt Creation in Congenital Heart Disease: Different Indications, Various Modifications, but Common Technical Challenges.

Matija Bakoš, Stanimir Georgiev, Kerstin Wustman, Paul Phillip Heinisch, Kristina Borgmann, Dunja Renner, Andreas Eicken, Julia Lemmer, Peter Ewert, Katarzyna Gendera

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Matija BakošDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Stanimir GeorgievDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Kerstin WustmanDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Paul Phillip HeinischDepartment of Cardiovascular Surgery, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Kristina BorgmannDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Dunja RennerDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Andreas EickenDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Julia LemmerDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Peter EwertDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany.
Katarzyna GenderaDepartment of Pediatric Cardiology and Congenital Heart Defects, German Heart Center, TUM University Hospital, Technical University of Munich, Munich, Germany. gendera@dhm.mhn.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Percutaneous creation of an aorto-pulmonary (AP) shunt has been explored in preclinical models for over 15 years, yet its clinical application remains limited. Surgical AP shunts are widely used to augment pulmonary blood flow in cyanotic congenital heart disease, but repeated thoracic operations and general anesthesia carry substantial risks in critically ill or surgically complex patients. A less invasive transcatheter alternative could therefore represent a transformative option. We report a case series of two pediatric patients in whom a percutaneous connection between the aorta and pulmonary artery was successfully established. Indications were severe cyanosis due to compromised pulmonary blood flow in one child and suprasystemic pulmonary arterial hypertension requiring decompression in the other. The procedures were technically feasible and resulted in the intended immediate hemodynamic effects, either by enhancing pulmonary perfusion or by enabling right-to-left shunting for right heart decompression. Conceptually, percutaneous AP shunt creation parallels the transcatheter Potts shunt, which is increasingly recognized as a therapeutic option in pulmonary arterial hypertension. Both approaches establish controlled communication between the aorta and pulmonary artery, adapted to distinct physiological settings. Our report represents, to our knowledge, the first description of percutaneous AP shunt creation to improve pulmonary blood flow and oxygenation in congenital heart disease, as well as the first percutaneous connection between the ascending aorta and the pulmonary artery. These cases illustrate the technical feasibility of catheter-based AP shunt creation in selected pediatric patients and support further evaluation of this approach.

Indexed as

ChildrenCongenital heart diseaseCyanosisPercutaneous AP shuntPulmonary hypertension

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.