Evidence map›Paper›PMID 42908598›Full record

ArticleFrontiers in ophthalmology2026

Classification of cystoid macular edema status from retinal vasculitis fluorescein angiography images using a convolutional neural network.

Celina Wang, Koushani Chakrabarty, Stephen D Anesi, Peter Y Chang

Abstract read
In one paragraph

Article in Frontiers in ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Celina WangMilton Academy, Milton, MA, United States.
Koushani ChakrabartyDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, United States.
Stephen D AnesiMassachusetts Eye Research and Surgery Institution, Waltham, MA, United States.
Peter Y ChangMassachusetts Eye Research and Surgery Institution, Waltham, MA, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Cystoid macular edema (CME) is a vision-threatening complication of retinal vasculitis, a rare inflammatory disease for which large imaging datasets are difficult to obtain. Detection of CME on fluorescein angiography (FA) requires expert interpretation, motivating automated image-based approaches to support clinical decision-making. Deep learning methods, particularly convolutional neural networks (CNNs), have shown strong performance in medical image analysis but are constrained by limited labeled data in rare diseases. Transfer learning may mitigate this limitation by adapting pretrained models to small, task-specific datasets. Methods: We analyzed 207 de-identified late-phase 55° FA images from 117 patients with retinal vasculitis. The primary target was concurrent patient-level CME status, established through specialist review of clinical records and optical coherence tomography obtained at the same clinical visit as FA. A patient was classified as CME-positive when CME was present in at least one eye. An ImageNet-pretrained ResNet-18 was evaluated using five-fold nested, patient-level cross-validation. Within each outer-development cohort, 144 candidate configurations were compared by four-fold inner cross-validation and selected according to mean inner-validation AUROC. Each selected configuration was evaluated only on its corresponding untouched outer-test fold. Results: Across 117 pooled patient-level outer-test predictions, the model-selection pipeline achieved an AUROC of 0.708 (95% CI, 0.610-0.802), an AUPRC of 0.626 (95% CI, 0.493-0.755), and an accuracy of 0.726 (95% CI, 0.641-0.803). Sensitivity was 0.694 (95% CI, 0.558-0.822), specificity was 0.750 (95% CI, 0.643-0.853), and the F1 score was 0.680 (95% CI, 0.563-0.780). Exploratory Grad-CAM analysis visualized regions associated with model predictions. Discussion: The nested model-selection pipeline showed moderate discrimination with a relatively balanced operating profile and slightly higher specificity than sensitivity. Clinically relevant false-positive and false-negative errors, together with the absence of external validation, preclude clinical deployment.

Indexed as

convolutional neural network (CNN)cystoid macular edema (CME)fluorescein angiographygrad-cammachine learningpatient-level cross-validationretinal vasculitistransfer learning

Identifiers

PMID42908598
PMCPMC13683005

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.