Evidence map›Paper›PMID 42905756›Full record

ArticlePloS one2026

Validation and optimisation of wearable accelerometer data pre-processing for digital measure implementation and development.

Joss Langford, Jia Ying Chua, Ian Long, Alan C Williams, Melvyn Hillsdon

Abstract readValidation Study
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Joss LangfordDepartment of Public Health and Sport Sciences, University of Exeter, Exeter, United Kingdom.ORCID https://orcid.org/0000-0002-3204-5866
Jia Ying ChuaActivInsights Limited, Kimbolton, Cambridge, United Kingdom.
Ian LongStoat Group Limited, Devon, United Kingdom.
Alan C WilliamsActivInsights Limited, Kimbolton, Cambridge, United Kingdom.
Melvyn HillsdonDepartment of Public Health and Sport Sciences, University of Exeter, Exeter, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The increasing use of accelerometers as digital health technologies in clinical trials and clinical care is driving the need for data processing to meet medical standards. The aim of this study was to create and test a modular pipeline for the pre-processing of high-resolution accelerometry that assures the quality, transparency and traceability of digital measures from sensor-level data. The objective is for the pipeline to be a foundational layer in the development, implementation and comparison of measures. The study developed the open GENEAcore package to meet the requirements of regulators, verifying the engineering implementation and analytically validating outputs against reference datasets. Early stages included the optimisation of calibration and non-wear detection. Data-driven detection of behavioural transitions was then validated to give direct bout outputs without the need to identify rules for epoch aggregation and interruptions. The utility for measure development was shown by comparing two algorithms for the characterisation of activity intensity in both the epoch and bout paradigms. Non-wear was detected with a balanced accuracy of 92.3% and the commonly used 13mg acceleration standard deviation threshold was empirically validated with a sensitivity analysis for the first time. The detection of transitions proved reliable with 99% detected, on average, within 2 seconds of their occurrence to give a mean expected event duration of 68.6s from a log-normal distribution. The different activity intensity algorithms were more than 99% concordant during movement but their outputs diverged in low movement conditions. Importantly, variable duration bouts created 31% higher daily activity durations compared to 1-second epochs. This evaluation of pre-processing steps has confirmed the attention to detail required to create robust and reproducible results for later clinical validation where small changes in an algorithm or its implementation may have clinically meaningful consequences.

Indexed as

AccelerometryWearable Electronic DevicesAlgorithmsCalibrationDigital HealthHumansReproducibility of Results

Identifiers

PMID42905756
PMCPMC13686512

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.