Evidence map›Paper›PMID 42904258›Full record

ArticleJournal of electrical bioimpedance2026

Electromagnetic validation of a multichannel coplanar four-electrode bioimpedance sensing platform for perfused 3D tumor-on-chip systems.

Félix Royer, Thomas Meynard, Robin Houssier, Jérôme Vicogne, Ørjan G Martinsen, Isabelle Van Seuningen, Vincent Senez

Abstract read
In one paragraph

Article in Journal of electrical bioimpedance, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Félix RoyerUniv. Lille, Inserm, CHU Lille, CNRS, U1366-UMR9020 - CRCLille, F-59000 Lille, France.
Thomas MeynardUniv. Lille, Inserm, CHU Lille, CNRS, U1366-UMR9020 - CRCLille, F-59000 Lille, France.
Robin HoussierUniv. Lille, Inserm, CHU Lille, CNRS, U1366-UMR9020 - CRCLille, F-59000 Lille, France.
Jérôme VicogneUniv. Lille, CNRS, Inserm, CHU Lille, IPL, U1019-UMR9017- CIIL, F-59000 Lille, France.
Ørjan G MartinsenDepartment of Physics, University of Oslo, Oslo, Norway.
Isabelle Van SeuningenUniv. Lille, Inserm, CHU Lille, CNRS, U1366-UMR9020 - CRCLille, F-59000 Lille, France.
Vincent SenezUniv. Lille, Inserm, CHU Lille, CNRS, U1366-UMR9020 - CRCLille, F-59000 Lille, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional tumor-on-chip systems better reproduce the spatial organization of tumor cells within extracellular-matrix-based microenvironments than conventional two-dimensional cultures, yet their integration with quantitative, non-destructive monitoring tools remains limited. Electrical bioimpedance provides a label-free approach for real-time assessment of living 3D tissues, but its implementation in perfused millimeter-scale microfluidic environments requires rigorous electrical and geometrical validation. In this study, we designed and electromagnetically validated an integrated coplanar four-electrode bioimpedance sensor embedded within a perfused 3D tumor-on-chip platform compatible with collagen-based hydrogels. Three-dimensional finite-element simulations were used to compute sensitivity fields and quantify the effective measurement volume. Calibration with conductivity standards showed quantitative agreement between experimental measurements and numerical predictions, with relative deviations below 10%, enabling reliable extraction of the cell constant. Chamber height was identified as the dominant geometrical parameter affecting impedance magnitude, whereas lateral misalignment had limited impact. Temperature-dependent conductivity changes induced impedance drifts of up to 25% during thermal equilibration, highlighting the need for strict temperature control. Acellular collagen I hydrogels exhibited concentration-dependent impedance variations, while increased gel loading before chamber closure modified impedance, likely through matrix compression and reorganization. These results demonstrate that the extracellular matrix significantly contributes to the measured electrical response. In static 3D cultures, embedding pancreatic cancer cells within collagen I produced a reproducible decrease in impedance magnitude at 10 kHz compared with acellular controls, confirming a measurable cell-dependent baseline shift. Under continuous perfusion, gradual cellular evolution did not generate a reproducible impedance trajectory, whereas Triton X-100-induced cell disruption increased impedance toward the acellular collagen I baseline. Overall, this study demonstrates that coplanar impedance sensing can detect cell-dependent baseline differences and strong endpoint perturbations in millimeter-scale 3D tumor models. However, dynamic impedance variations under perfusion remain influenced by matrix, thermal, geometrical, and conductive-pathway contributions, emphasizing the need for careful calibration before biological interpretation.

Indexed as

3D hydrogel culturecoplanar four-electrodeElectrical impedance spectroscopysensitivity field / lead-field analysistumor-on-chip

Identifiers

PMID42904258
PMCPMC13682677

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.