ArticleCentral European journal of urology2026
Effect of leaded gloves on patient and surgeon radiation exposure in percutaneous nephrolithotomy: A prospective pilot study.
Article in Central European journal of urology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Ionizing radiation exposure is a significant occupational hazard for urologists performing percutaneous nephrolithotomy (PCNL). Surgeon hands are particularly vulnerable during fluoroscopic access. Leaded gloves are a proposed mitigation strategy. This prospective pilot study evaluated surgeon hand and patient collar radiation exposure during PCNL with standard vs leaded gloves. Material and methods: Twenty patients were prospectively allocated to standard or leaded glove groups in sequential fashion. All cases were performed by a single high-volume endourologist with patients in the prone position. Clinical variables including BMI, operative time, stone size, and fluoroscopy dose were recorded. Surgeon hand exposure was measured using ring dosimeters. Patient exposure was measured with clip-on dosimeters at the collar, reported as deep dose equivalent (DDE), lens dose equivalent (LDE), and shallow dose equivalent (SDE). Results: At baseline, patient BMI (p = 0.005) and fluoroscopy radiation dose (p <0.001) were greater in the standard glove group. There was no significant difference in surgeon hand exposure at the right (p = 0.143) or left hand (p = 0.608). Leaded gloves were associated with a significant increase in patient collar radiation at DDE (p = 0.002), LDE (p = 0.009), and SDE (p = 0.009). Conclusions: In this pilot study, leaded glove use was associated with a significant and consistent increase in patient collar radiation across all measurement depths. The non-significant reduction in surgeon hand exposure should be interpreted cautiously given limited statistical power. These findings do not support routine leaded glove use during PCNL, and adequately powered studies are needed to confirm these findings and identify optimal radiation protection strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.