ArticleJournal of orthopaedic surgery and research2026
Biomechanical and finite element analysis of a novel annular multi-axial locking plate for patellar fracture fixation.
Article in Journal of orthopaedic surgery and research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTraditional tension band structures for patellar fractures have multiple complications such as wires lossening and soft tissue irritation. In response to the above problems, a new type of annular multi-axis locking plate has been designed for the treatment of patellar fractures. This study aims to compare the biomechanical performance of two methods for stabilizing patellar fractures.
methodsA three-dimensional finite element model was established to evaluate the biomechanical performance of annular multi-axis locking steel plate fixation for patellar fractures at knee flexion angles of 20, 45, and 90°. Furthermore, four pairs of matched fresh-frozen cadaveric transverse patellar fracture models (AO/OTA 34B1) stabilized with annular multi-axis locking steel plates (AMALP, experimental group) and cable tension band (CTB, control group) were established to compare the biomechanical performance of the two internal fixation methods. Dynamic fatigue testing was performed by moving the knee from 90to 0° under a load of 6 kg until 200 cycles were completed or the internal device failures. Using a testing machine to evaluate the ultimate force required for the failure of each internal device at knee flexion angles of 20, 45, and 90°. The fracture displacement distance and the ultimate load were recorded.
resultsThe outcome of finite element analysis (FEA) demonstrated the max value of Von-Mises stress of the three knee flexion angles simulated were between 45.328 MPa to 109.191 MPa,which is lower than the yield strength value of the plate(351-429 MPa).The displacement value was between 0.1645 and 0.3487 mm, which is acceptable according to clinical criterion(< 2 mm).After 200 cycles of knee flexion fatigue testing, neither group showed any failure of internal fixation. After 100, 150, and 200 cycles of knee flexion fatigue testing, the displacement of the fracture on the anterior surface (0.36 ± 0.05 mm, 0.41 ± 0.04 mm, 0.49 ± 0.08 mm) and joint surface (0.29 ± 0.05 mm, 0.36 ± 0.07 mm, 0.44 ± 0.09 mm) in AMALP were significantly lower than those in the CTB (anterior surface: 0.54 ± 0.09 mm, 0.66 ± 0.11 mm, 0.73 ± 0.09 mm) (joint surface: 0.45 ± 0.06 mm, 0.52 ± 0.06 mm, 0.59 ± 0.08 mm) (P < 0.05).Across all three knee flexion angles (20, 45, and 90°), the AMALP exhibited significantly higher ultimate failure loads (812.40 ± 46.62 N, 546.59 ± 45.22 N, and 370.52 ± 36.41 N, respectively) compared to the CTB(669.60 ± 65.43 N, 423.71 ± 39.46 N, and 264.57 ± 48.15 N, respectively; P < 0.05).
conclusionThe novel plate features an anatomically contoured profile that closely conforms to the patellar surface, adhering to the principles of tension-band fixation. The screw trajectories are designed with a centripetal orientation, generating intrinsic compressive forces that facilitate axial compression across the fracture site. This not only helps maintain patellar integrity but also enhances knee joint stability, aligning well with established biomechanical principles. Collectively, these design characteristics position the novel plate as a promising new internal fixation option for the treatment of patellar fractures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.