Evidence map›Paper›PMID 42900558›Full record

ArticleJournal of applied clinical medical physics2026

Geometric and dosimetric effects of an automated clustering and plan optimization pipeline for multiple brain metastasis radiosurgery.

Adam D Yock, Guozhen Luo, Sean All, Austin N Kirschner, Cornelis Kamerling

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adam D YockDepartment of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Guozhen LuoDepartment of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.ORCID https://orcid.org/0000-0001-5460-2099
Sean AllDepartment of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Austin N KirschnerDepartment of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Cornelis KamerlingBrainlab SE, Munich, Bavaria, Germany.

Funding

Brainlab SE, Munich, Germany
6 · The paper itself

Abstract

backgroundTreating multiple brain metastases simultaneously with single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) can streamline treatment planning and delivery. However, it can also result in targets at large distances from the isocenter, increasing sensitivity to rotational setup errors and requiring wider collimator leaves. Grouping the targets and treating each group with its own plan retains the practical benefits of SIMT SRS while mitigating the concerns of targets at large distances off-isocenter. PURPOSE: This work presents a prototype of a newly integrated treatment planning pipeline that automatically clusters targets into groups and subsequently optimizes a plan for each group simultaneously. Treatment scenarios featuring varying numbers of isocenters were compared.

methodsTwenty-nine treatment courses for patients receiving SRS for 3-15 brain metastases were retrospectively analyzed. Multiple treatment scenarios were prepared for each patient-course by grouping targets into 1-5 isocenters using k-means clustering. PTV margins were added using two methods, one with a magnitude that varied with distance to the isocenter, and a second with a constant 1-mm magnitude. A non-clinical, command-line version of the Brainlab Elements Multiple Brain Mets SRS software was used to optimize plans within each scenario simultaneously. Cumulative doses were analyzed in terms of geometric values (target distances to isocenter, total PTV volume), dosimetric values (volume of normal brain (brain-GTVs) receiving 5, 8, 10, 12, and 18 Gy (V

resultsAs the number of isocenters increased, distances from the targets to the isocenters decreased, and the proportion of targets within a given distance increased. For example, 36%, 77%, 94%, 99%, and 100% of targets were within 4 cm of the isocenter for 1-5 isocenters, respectively. For the variable margin method, the total PTV volume relative to the single-isocenter scenario had a median decrease of 17.5, 24.3, 31.6, and 37.8% for 2-5 isocenters, respectively. Similarly, the relative change in the normal brain dose metrics decreased with increasing number of isocenters (e.g. V

conclusionThe SIMT SRS treatment planning pipeline presented here features automatic grouping of targets followed by automatic dose optimization of up to five isocenters. By quantifying the geometric, dosimetric, and logistical effects of adding isocenters, this pipeline can empower clinicians to make resource-conscious treatment decisions optimal for each patient.

Indexed as

Brain NeoplasmsRadiosurgeryRadiotherapy Planning, Computer-AssistedAlgorithmsCluster AnalysisClustering AlgorithmsHumansOrgans at RiskPrognosisRadiotherapy DosageRadiotherapy, Intensity-ModulatedRetrospective Studiesbrain metastasesradiosurgerySIMTsingle‐isocenter multiple‐targetSRS

Identifiers

PMID42900558
PMCPMC13682620

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.