ArticleJournal of ultrasound2026
Shear-wave elastography combined with ultrasound BI-RADS improves diagnostic accuracy in breast lesion characterization: a prospective cross-sectional study.
Article in Journal of ultrasound, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo compare BI-RADS and shear-wave elastography (SWE) for differentiating benign from malignant breast lesions and assess whether adding maximum elasticity (Emax) improves discrimination and biopsy decisions.
methodsIn this diagnostic accuracy study (May 2023-August 2024), 87 adults with 93 breast lesions underwent B-mode BI-RADS and SWE (Emax, Emean, Emin). ROC analysis and logistic regression incorporating BI-RADS and Emax were performed. Patient-level bootstrap resampling with 2,000 iterations provided optimism correction.
resultsEleven lesions (11.8%) were malignant. Median Emax and Emean were higher in malignant lesions (200.1 vs 105.7 kPa, P = 0.003; 103.1 vs 70.7 kPa, P = 0.004). AUCs were 0.766 for BI-RADS, 0.774 for Emax, 0.767 for Emean, and 0.697 for Emin; pairwise differences were nonsignificant (all P ≥ 0.153). The model had an AUC of 0.853 (95% CI, 0.754-0.951) and optimism-corrected AUC of 0.844. AUC gain was 0.087 (0.016-0.158; P = 0.017), with corrected gain of 0.077. At a 2% risk threshold, sensitivity was 100%, but biopsy recommendations increased from 41 to 55. The BE1 rule reduced biopsy recommendations by six, avoiding five benign biopsies but missing one carcinoma.
conclusionAdding Emax to BI-RADS improved discrimination, with the gain persisting after validation. However, only 11 lesions were malignant, yielding imprecise estimates. No operating point reduced biopsy recommendations without sacrificing sensitivity. The model and SWE cut-offs require external validation. IMPLICATION OF PRACTICE: SWE may be used as an adjunct to BI-RADS for characterization, but Emax thresholds and the combined model should not yet guide biopsy downgrading. Larger prospective studies with external validation are needed before implementation.