Evidence map›Paper›PMID 42899374›Full record

ArticleJournal of clinical laboratory analysis2026

Standardization of the Monocyte Monolayer Assay: Lessons Learned From Laboratory Optimization and Literature Review.

Shamee Shastry, Kavya Babu, Deepika Chenna, Ganesh Mohan, Kartik Iyer

Abstract read
In one paragraph

Article in Journal of clinical laboratory analysis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shamee ShastryDepartment of Immunohematology and Blood Transfusion, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.ORCID https://orcid.org/0000-0001-9796-2326
Kavya BabuDepartment of Immunohematology and Blood Transfusion, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.ORCID https://orcid.org/0009-0002-0527-8864
Deepika ChennaDepartment of Immunohematology and Blood Transfusion, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.ORCID https://orcid.org/0000-0003-1461-5498
Ganesh MohanDepartment of Immunohematology and Blood Transfusion, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.ORCID https://orcid.org/0000-0002-8728-9307
Kartik IyerDepartment of Immunohematology and Blood Transfusion, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India.

Funding

Terumo Penpol Private Limited
6 · The paper itself

Abstract

objectivesSeveral variables influence the outcome of cellular assays. We conducted a comprehensive literature review to identify the factors affecting the Monocyte Monolayer Assay (MMA) and subsequently standardized the assay through systematic in-house laboratory trials.

methodsThe study was conducted in two phases. Phase 1 involved a literature review using PubMed and Scopus databases to identify factors influencing the assay. Phase 2 included experimental trials to evaluate the effects of these factors. Monocytes were isolated from buffy coat bags, and assay parameters, such as centrifugation speed, monocyte adherence conditions, RBC sensitization, incubation time, and staining, were systematically standardized. A blinded evaluation was employed for slide reading to assess the influence of procedural factors on assay reliability.

resultsA literature review using the PubMed and Scopus databases identified key variables influencing MMA performance. Twelve sequential trials were conducted to identify the effects of these variables on assay outcome. Optimal centrifugation speed and time was 600 × g for 15 min, and the use of four buffy coat bags improved monocyte yield to 8.3 × 10

conclusionThis study emphasizes the importance of standardizing the MMA procedure before implementation. Optimizing the parameters to ensure enhanced monocyte yield, reduced cell lysis, and reliable interpretation for assessing the clinical significance of red cell alloantibodies is essential.

Indexed as

antibodiescellular assaylaboratory standardizationmedical diagnosticsquality diagnosticsquality education

Identifiers

PMID42899374
PMCPMC13681279

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.