Evidence map›Paper›PMID 42897432›Full record

ArticleAnnals of biomedical engineering2026

Turning-Point Impact Compromises the Biomechanical Integrity of Cortical Bone During Oscillating Sawing.

Han Wang, Urara Satake, Toshiyuki Enomoto

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Han WangDivision of Mechanical Engineering, Graduate School of Engineering, The University of Osaka, 2-1, Yamada-oka, Suita, Osaka, 565-0871, Japan.ORCID http://orcid.org/0000-0002-8265-3739
Urara SatakeDivision of Mechanical Engineering, Graduate School of Engineering, The University of Osaka, 2-1, Yamada-oka, Suita, Osaka, 565-0871, Japan. satake@mech.eng.osaka-u.ac.jp.
Toshiyuki EnomotoDivision of Mechanical Engineering, Graduate School of Engineering, The University of Osaka, 2-1, Yamada-oka, Suita, Osaka, 565-0871, Japan.

Funding

Japan Society for the Promotion of Science JP24K00777Japan Society for the Promotion of Science JP25K23426
6 · The paper itself

Abstract

purposeOscillating bone sawing is widely used in orthopedic surgery, where preserving the mechanical integrity of the prepared bone surface is essential for implant stability. However, the influence of turning-point impacts on the biomechanical integrity of the prepared bone surface remains unclear. This study aimed to quantify the effects of turning-point impacts on surface integrity and the mechanical properties of cortical bone.

methodsOscillating sawing experiments were performed on bovine cortical bone using conventional and optimized trajectories. Dynamic sawing forces were measured to quantify turning-point impact events. Surface damage was characterized by scanning electron microscopy and digital microscopy. Local and global mechanical properties were evaluated by flat-punch and conventional compression tests, respectively.

resultsThe conventional trajectory generated pronounced turning-point impact forces, accompanied by extensive surface cracks and breakout defects. In contrast, the optimized trajectory significantly suppressed turning-point impact forces (p < 0.001) and preserved groove wall surface integrity. Consequently, both the local (p < 0.001) and global (p = 0.001) compressive strengths increased, whereas the elastic modulus remained unchanged. These findings indicate that turning-point impacts primarily reduce failure strength by introducing localized microstructural defects while largely preserving bulk elastic stiffness.

conclusionTurning-point impacts compromise the biomechanical integrity of cortical bone by reducing the load-bearing capacity of implant-relevant bone surfaces. Suppressing these transient impacts helps preserve implant-relevant bone surface integrity and may improve the stability of the bone-implant interface. These findings provide a biomechanical basis for future real-time impact monitoring and adaptive control in surgical robotics to prevent impact-induced damage.

Indexed as

Biomechanical integrityCompressive strengthCortical boneOscillating bone sawingSurface damageTurning-point impact

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.