ArticleMedical & biological engineering & computing2026
Visual estimation of guidewire contact forces by integrating multi-scale features and region mask.
Article in Medical & biological engineering & computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
During percutaneous coronary intervention (PCI), the contact force between the guidewire and the vessel wall is a key mechanical factor in vessel injury, yet it cannot be measured directly with conventional imaging. Although sensor-based methods measure the contact force directly, they increase both the complexity and the cost of the instrumentation. A sensorless guidewire contact force estimation method is therefore proposed, in which multi-scale feature extraction is combined with region mask mean pooling to learn an end-to-end mapping from conventional planar images to the contact force in each of the four predefined contact regions. The proposed method is evaluated on a dataset of 343 samples acquired on a 3D-printed vessel phantom, achieving a mean absolute error (MAE) of 0.861 g and a root mean square error (RMSE) of 1.036 g. Ablation experiments show that the region mask reduces the MAE by 79% relative to the identical architecture without the region mask. Requiring neither additional sensing hardware nor complex physical modeling, the method estimates the contact force from visual information alone. These results support the feasibility of vision-based sensorless contact force estimation and suggest a possible route toward force feedback in interventional procedures.
Indexed as
Identifiers
42897361What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.