Evidence map›Paper›PMID 42894706›Full record

ArticleJournal of clinical and experimental dentistry2026

Biomechanical stability and monitoring technologies of implant-supported prosthetic components.

Jefferson David Melo de Matos, Mário Alexandre Coelho Sinhoreti, Mauricio Schneider, Robert Dobrin, Daher Antonio Queiroz

Abstract read
In one paragraph

Article in Journal of clinical and experimental dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jefferson David Melo de MatosDepartment of Biomaterials, Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, Sao Paulo, B.
Mário Alexandre Coelho SinhoretiDepartment of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School (FOP UNICAMP), Piracicaba, Sao Paulo, Brazil.
Mauricio SchneiderDepartment of Prosthodontics, Nova Southeastern University College of Dental Medicine, Fort Lauderdale, Florida, USA.
Robert DobrinDepartment of Prosthodontics, Nova Southeastern University College of Dental Medicine, Fort Lauderdale, Florida, USA.
Daher Antonio QueirozDepartment of Restorative Sciences and Public Health Dentistry, Nova Southeastern University College of Dental Medicine, Fort Lauderdale, Florida, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Mechanical stability is a critical factor for the long-term success of implant-supported rehabilitations. The maintenance of preload within the implant-abutment complex plays a fundamental role in preventing prosthetic complications, particularly screw loosening and loss of joint stability. Advances in monitoring technologies, including ultrasonic methods, piezoelectric sensors, and electromechanical impedance techniques, have introduced new possibilities for the early detection of biomechanical alterations in implant-supported prosthetic components. Materials and Methods: A structured narrative review was performed through comprehensive literature searches in PubMed/MEDLINE, Scopus, Web of Science and SciELO databases. The retrieved literature was critically analyzed according to biomechanical principles, preload maintenance, screw loosening mechanisms and emerging monitoring technologies. Results: The reviewed studies demonstrated that preload maintenance is essential for the biomechanical stability and longevity of implant-supported rehabilitations. Prosthetic screw loosening was identified as a prevalent mechanical complication, especially under cyclic and non-axial loading conditions. Internal conical and Morse taper connections generally showed improved preload maintenance compared with external hexagon systems. Additionally, ultrasonic monitoring, piezoelectric sensors, and electromechanical impedance methods demonstrated potential for early detection of preload loss and biomechanical instability. Although promising, most monitoring technologies remain limited to experimental investigations. Conclusions: Mechanical stability in implant-supported rehabilitations is strongly associated with preload preservation and implant-abutment integrity. Advanced monitoring technologies show promising potential for improving the early diagnosis of biomechanical instability; however, further prospective clinical studies are required before routine clinical implementation can be recommended.

Indexed as

biomechanicsdental abutmentsDental implantsdental prosthesisimplant-supportedprosthesis failure.

Identifiers

PMID42894706
PMCPMC13677092

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.