ArticleSurgery in practice and science2026
Intraoperative specimen ultrasonography for margin assessment in breast conserving surgery in comparison with specimen mammography.
Article in Surgery in practice and science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Intra-operative specimen ultrasonography (IOUS) has been proposed as a cost-effective tool to assess surgical margins during breast-conserving surgery (BCS). We aimed to evaluate the diagnostic accuracy of IOUS in assessing radial margins in patients undergoing wide local excision (WLE) for non-palpable breast lesions and to compare its performance with specimen mammography (SM). Patients and Methods: This was a retrospective analysis of prospectively collected data from patients undergoing WLE for invasive breast cancer and mass-forming Ductal Carcinoma In Situ (DCIS) at a single tertiary referral centre between January 2018 and December 2022. The study protocol and outcomes were established prospectively in 2018, prior to commencement of data collection. All eligible patients undergoing intra-operative ultrasound (IOUS) and specimen mammography (SM) during the study period were prospectively identified, with exclusions subsequently applied according to the predefined eligibility criteria. Clinical, operative and imaging data were collected prospectively throughout the study period. All patients were operated by the same senior surgeon. Specimen ultrasound was performed intra-operatively by the operating surgeon. Radiological margins were considered clear when the distance from the tumour edge was >10 mm and close when ≤10 mm. When a close radiological margin was identified, an additional cavity shave was performed. IOUS findings were subsequently compared with the radiological margin assessment on specimen mammography and with final histopathological margin status. The primary outcome was the ability of IOUS and SM to identify radiologically close radial margins (≤10 mm), using final histopathological margin status as the reference standard. Results: 137 lesions (132 patients) were included in the study. The median age of patients was 66 (range: 33-86) years. 89 patients (67.5%) were screen detected. 126 (92%) lesions were invasive tumours. The median size of lesions on preoperative imaging was 15 (range: 5-18) mm. 548 radial margins were assessed, of which 22 (4%) were positive on histological analysis. IOUS demonstrated radiologically clear 517 margins (SM 513 margins) and radiologically close in 31 margins (SM in 35 margins). The sensitivity of IOUS was 68.2% (SM 72.7%) p = 0.61, and specificity 96.9%. (SM 96.4%) p = 1.0. IOUS had a negative predictive value of 98.6% (SM 98.8%). Conclusion: Intraoperative ultrasound demonstrates comparable diagnostic accuracy to specimen mammography for intra-operative margin assessment in non-palpable breast lesions. Its high specificity and negative predictive value support its reliability in excluding margin involvement. IOUS represents a rapid, accessible, and cost-effective alternative to SM, particularly in centres without specimen radiography or in resource-limited settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.