ArticleJournal of medical physics
Characterization and Validation of MicroDiamond Detectors in Patient-specific Quality Assurance of Magnetic Resonance-guided Stereotactic Radiotherapy.
Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: A dosimetric performance analysis of microDiamond (MD) detector in magnetic resonance imaging linear accelerators (MR-Linac) was performed to evaluate its utility for patient-specific quality assurance (PSQA) in stereotactic radiotherapy (SRT). Methods: Output factors (OFs), depth dose curves, and dose profiles for field sizes from 1 cm × 1 cm to 10 cm × 10 cm were measured in an Elekta Unity 1.5 T MR-Linac. Measurements were conducted using an MR-Safe three-dimensional (3D) water phantom with a PTW Semiflex 3D ionization chamber and a PTW MD detector. Angular response was assessed for orientations perpendicular to the beam and parallel to the magnetic field; correction factors were determined for gantry angles from 0° to 360° in 20° increments. Detectors were cross-calibrated against a 0.6 cc Farmer chamber, and patient-specific point-dose verification was performed for SRT plans. Results: Average Conclusion: The MD detector was successfully validated for MR-Linac. Asymmetric angular dependence due to the Lorentz force was confirmed, necessitating gantry angle-specific corrections for dose estimation. The MD detector demonstrated superior accuracy for small-field SRT targets, confirming its significance for precise PSQA.