Evidence map›Paper›PMID 42890938›Full record

ArticleJournal of medical physics

Independent Three-dimensional Dose Calculation from Log Files for Breast VMAT: A Measurement-free Quality Assurance Approach.

Rosa Angelica Petit Sevilla, Oscar Abel Apaza Blanco, Nayron Medeiros Soares, Maximiliano Musso, Ezequiel Agustín Cabrera Lacey, Luis C Bohorquez, Lucy Wolfsberger, Maria José Almada, Carlos Daniel Venencia

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rosa Angelica Petit SevillaDepartment of Medical Physics, Instituto Zunino, Córdoba, Argentina.
Oscar Abel Apaza BlancoMarie Curie Foundation, Zunino Institute, Córdoba, Argentina.
Nayron Medeiros SoaresDepartment of Medical Physics, Instituto Zunino, Córdoba, Argentina.
Maximiliano MussoDepartment of Medical Physics, Instituto Zunino, Córdoba, Argentina.
Ezequiel Agustín Cabrera LaceyDepartment of Medical Physics, Instituto Zunino, Córdoba, Argentina.
Luis C BohorquezDepartment of Medical Physics, LAP of America Laser Applications, Boynton Beach, FL, USA.
Lucy WolfsbergerDepartment of Medical Physics, LAP of America Laser Applications, Boynton Beach, FL, USA.
Maria José AlmadaDepartment of Medical Physics, Instituto Zunino, Córdoba, Argentina.
Carlos Daniel VenenciaDepartment of Medical Physics, Instituto Zunino, Córdoba, Argentina.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of this study was to evaluate and validate a measurement-free patient-specific quality assurance (PSQA) approach for volumetric modulated arc therapy (VMAT) breast cancer treatments based on independent three-dimensional (3D) dose calculation from Digital Imaging and Communications in Medicine (DICOM) plans and linear accelerator log files. Materials and Methods: Seventy clinical breast VMAT plans (36 left-sided and 34 right-sided) were retrospectively analyzed. Independent 3D dose calculations were performed using RadCalc v7.3 based on the DICOM treatment plan (independent dose calculation [IDC] RTPlan) and on delivery log files acquired during the first treatment fraction (IDC LOGs). Results were compared with portal dosimetry (two-dimensional [2D]) and fluence-based analysis. Gamma passing rates (GPRs) were evaluated using 3%/2 mm and 2%/2 mm criteria under action (90%) and tolerance (95%) limits. Receiver operating characteristic (ROC) analysis was performed to evaluate the discriminatory capability. Sensitivity to delivery errors was investigated by introducing controlled multileaf collimator (MLC) shifts (0.5-2.0 mm) and collimator rotation errors (1°-3°). Results: All PSQA methods met the TG-218 action limit (GPR ≥ 90%) at 3%/2 mm. Under the stricter 2%/2 mm criterion, statistically significant differences among quality assurance methods were observed ( Conclusions: Independent 3D dose calculation is a reliable PSQA approach for breast VMAT, showing higher sensitivity than conventional 2D methods.

Indexed as

Breast radiotherapylog file analysispatient-specific quality assurancethree-dimensional dose calculation

Identifiers

PMID42890938
PMCPMC13675032

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.