Design and Bench Evaluation of a Sensor-Integrated Prosthetic-Leg Prototype.

Turar Seitkassymov, Yerkebulan Nurgizat, Nursultan Zhetenbayev, Aidos Sultan, Gani Sergazin, Kassymbek Ozhikenov

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Turar SeitkassymovDepartment of Robotics and Technical Means of Automation, Satbayev University, Almaty 050013, Kazakhstan.
Yerkebulan NurgizatDepartment of Robotics and Technical Means of Automation, Satbayev University, Almaty 050013, Kazakhstan.ORCID 0000-0002-9712-5592
Nursultan ZhetenbayevDepartment of Robotics and Technical Means of Automation, Satbayev University, Almaty 050013, Kazakhstan.ORCID 0000-0003-3358-1182
Aidos SultanDepartment of Robotics and Technical Means of Automation, Satbayev University, Almaty 050013, Kazakhstan.ORCID 0000-0001-7548-2954
Gani SergazinDepartment of Robotics and Technical Means of Automation, Satbayev University, Almaty 050013, Kazakhstan.
Kassymbek OzhikenovDepartment of Robotics and Technical Means of Automation, Satbayev University, Almaty 050013, Kazakhstan.

Funding

Ministry of Science and Higher Education of the Republic of Kazakhstan BR24992820
6 · The paper itself

Abstract

This study presents the design and preliminary bench evaluation of a sensor-integrated prosthetic-leg prototype. The platform combines a multi-material PAHT-CF/TPU 95A foot, articulated knee and ankle mechanisms, two surface electromyography channels, an MPU6050 inertial measurement unit, an Arduino Uno controller, and MG995 servomotors. EMG threshold crossings select discrete knee-servomotor commands, while an accelerometer-derived inclination estimate selects between two ankle-servomotor commands. The evaluation comprised exploratory finite-element analyses, separate static compression tests, and qualitative demonstrations of the sensor-to-actuator pathways. The foot model predicted a maximum displacement of 25.96 mm under 400 N, whereas a separate compression test recorded approximately 7 mm at 1000 N; these values do not constitute quantitative model validation because the loading, constraints, and displacement measures differed. The shank model produced a maximum equivalent stress of 23.89 MPa, and a separate shank-knee assembly test reached approximately 1.85 kN. The foot-ankle connection produced a stress estimate of 203.6 MPa against an assumed strength value of 60 MPa, identifying a critical design limitation. Functional observations demonstrated sensor-triggered command execution, but joint tracking accuracy, response time, actuator output under load, and control repeatability were not quantified. The prototype therefore provides an initial laboratory platform for investigating mechanical and sensing integration; structural redesign and quantitative bench testing are required before any load-bearing or clinical use can be considered.

Indexed as

Artificial LimbsBiosensing TechniquesLegProsthesis DesignBiomechanical PhenomenaElectromyographyFinite Element AnalysisHumansadditive manufacturingbench testingfinite-element analysisinertial measurement unitmulti-material footprosthetic-leg prototypesensor-triggered position commandsurface electromyography

Identifiers

PMID42884541
PMCPMC13667677

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.