ArticleSensors (Basel, Switzerland)2026
Embedded Cardiorespiratory Monitoring Using a 77 GHz FMCW Radar: On-Chip Multi-Timescale Tiny 1D CNN and Whole-Node Power Evaluation.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A 77-GHz radar can detect small chest movements induced by cardiac activity and respiration; however, typical systems transmit the acquired signals to an external computer for processing. This limits the development of autonomous and energy-efficient monitoring devices. This study presents a system in which radar signal processing, signal quality assessment, and heart rate (HR) and respiratory rate (RR) estimation are performed directly on the AWR1843 radar device. A Tiny 1D CNN used a 10-s observation window for HR and a 30-s window for RR, producing updated estimates every 1 s. The system was validated with 30 participants aged 18-72 years. The mean absolute error was 2.09 beats/min for HR and 1.05 breaths/min for RR. Compared with the implemented short-window FFT-based spectral estimator, the errors were reduced by 45.3% and 37.5%, respectively. INT8 quantization reduced the model weight size from 19.2 to 4.8 kB, the inference time from 4.6 to 1.9 ms, and the incremental energy per network execution from 2.7 to 0.9 mJ. However, this inference-level improvement did not produce a proportional reduction in whole-node power, which remained approximately 2.38 W because the continuously active radar front end and frame-level signal processing dominated the total power consumption. The system transmits only the estimated parameters and their associated reliability indicators. Consequently, the radar can operate as a standalone measurement node rather than continuously streaming raw data to an external computer.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.