Evidence map›Paper›PMID 42884464›Full record

ArticleSensors (Basel, Switzerland)2026

Standardized Short-Wave Infrared Hyperspectral Imaging for Non-Destructive Spectral Comparison of Coin Denominations, Design Variants, and Surface-Use Conditions.

Hsin-Che Wang, Kuo-Chih Su, Yi-Jing Sheen, Chiu-Chin Sung, Min-Yi Chou, Kuan-Jung Pan, Hsian-Min Chen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hsin-Che WangCenter for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
Kuo-Chih SuDepartment of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.ORCID 0000-0002-3632-0458
Yi-Jing SheenCenter for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
Chiu-Chin SungCenter for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
Min-Yi ChouCenter for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
Kuan-Jung PanCenter for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
Hsian-Min ChenCenter for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.ORCID 0000-0002-8409-3237

Funding

Taichung Veterans General Hospital TCVGH-1143919C, TCVGH-1153908C, TCVGH-YM1140119
6 · The paper itself

Abstract

Coins contain multiple types of information, including denomination, design variant, year of issue, and surface condition. This study established a standardized 900-1700 nm short-wave infrared hyperspectral imaging (SWIR-HSI) workflow for controlled and non-destructive spectral comparison of metallic coins. Twenty-five independent New Taiwan dollar (NT$10) coins were used to evaluate imaging position, coin side, and aperture setting. At position 13 on the reverse side, the mean spectral standard deviations were 0.192, 0.142, and 0.151 for F1.8, F2.8, and F4, respectively, and F2.8 was selected for subsequent measurements. Using the same NT$10 coin, support-material and in-plane rotation experiments produced spectral angle mapper (SAM) ranges of 0.232-1.087 and 0.132-0.581, respectively. Under the standardized conditions, the SAM value between one new and one circulated NT$10 coin was 0.729. Pairwise SAM values ranged from 0.260 to 1.680 among eight NT$10 design variants and from 0.458 to 2.449 among six denomination or special-year samples. An initial repeatability evaluation under the current experimental conditions, using three additional NT$10 coins and 24 acquisitions, yielded mean SAM values of 0.2450°, 0.6368°, and 0.3323° for repositioning, inter-day, and inter-operator comparisons, respectively, with an overall median spectral CV of 0.83%. These results quantitatively demonstrate that acquisition conditions affect SWIR spectral measurement and that selected coin samples exhibit measurable spectral differences under controlled conditions. The present study focuses on acquisition standardization and descriptive spectral comparison and does not establish validated coin classification, material identification, or surface-condition assessment.

Indexed as

acquisition standardizationcoin analysisnon-destructive testingshort-wave infrared hyperspectral imagingspectral angle mapperspectral comparison

Identifiers

PMID42884464
PMCPMC13667621

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.