Evidence map›Paper›PMID 42884343›Full record

ArticleSensors (Basel, Switzerland)2026

Validation of Smartphone-Based Photogrammetric 3D Body Scanning for Automated Anthropometric Measurements Compared with a Commercial Depth-Sensor-Based Body Scanner.

Ruting Cheng, Boyuan Feng, Chuhui Qiu, Joaquin A Calderon, Qing Pan, Yufan Liu, James K Hahn

Abstract readValidation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ruting ChengDepartment of Computer Science, The George Washington University, Washington, DC 20052, USA.ORCID 0000-0002-1442-7166
Boyuan FengDepartment of Computer Science, The George Washington University, Washington, DC 20052, USA.ORCID 0009-0008-7609-3801
Chuhui QiuDepartment of Computer Science, The George Washington University, Washington, DC 20052, USA.ORCID 0009-0008-7780-1291
Joaquin A CalderonDepartment of Obstetrics and Gynecology, The George Washington University, Washington, DC 20052, USA.ORCID 0000-0002-8025-534X
Qing PanDepartment of Biostatistics and Bioinformatics, The George Washington University, Washington, DC 20052, USA.ORCID 0000-0003-1253-0490
Yufan LiuSchool of Computing and Data Science, The University of Hong Kong, Hong Kong SAR, China.ORCID 0009-0007-8781-0282
James K HahnDepartment of Computer Science, The George Washington University, Washington, DC 20052, USA.ORCID 0000-0001-6535-8175

Funding

Advancing 3D optical body surface scan technology to assess physiological and psychological effects in highly obese populationR01DK129809 · NIDDK · GEORGE WASHINGTON UNIVERSITY · PI HAHN, JAMES K · 2021 to 2024
$2.2M
3D body shape analysis for predicting sarcopenia and obesity in older adultsR56AG089080 · NIA · GEORGE WASHINGTON UNIVERSITY · PI HAHN, JAMES K · 2024 to 2024
$333k
NIA NIH HHS R56 AG089080NIA NIH HHS R56AG089080NIDDK NIH HHS R01 DK129809NIDDK NIH HHS R01DK129809
6 · The paper itself

Abstract

The rapid and non-invasive nature of 3D body scanning has made it an important tool in healthcare applications. While smartphone-based photogrammetric reconstruction provides a low-cost and accessible alternative to commercial 3D body scanners, its performance for whole-body scanning remains insufficiently validated. Thus, we designed this paper to comprehensively validate the photogrammetric 3D scanning application by evaluating automatically extracted whole-body measurements and longitudinal body-shape monitoring. We evaluated a representative application, PolyCam, against the commercial depth-sensor-based Fit3D ProScanner using 144 pregnant participants scanned longitudinally throughout pregnancy. We designed an automatic circumference extraction pipeline to obtain measurements at four anatomical landmarks from paired 3D scans. A linear mixed-effects model was used to evaluate scanner effects and longitudinal body-shape changes. Measurement consistency was assessed using repeated PolyCam scans and tape measurements on a rigid mannequin. PolyCam demonstrated strong agreement with Fit3D with average biases below 16 mm, intraclass correlation coefficients above 0.8, and Pearson correlation coefficients above 0.9 across all landmarks. Both systems captured comparable longitudinal body-shape changes. Mannequin experiments showed mean biases below 3.5 mm and no significant differences from tape measurements. These findings support smartphone photogrammetry as a potential accessible alternative to commercial body scanners that is applicable for longitudinal 3D body-shape assessment.

Indexed as

AnthropometryImaging, Three-DimensionalPhotogrammetrySmartphoneFemaleHumansPregnancy3D body scanningdigital healthphotogrammetric reconstructionsmartphone-based scanning

Identifiers

PMID42884343
PMCPMC13667523

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.