Evidence map›Paper›PMID 42884333›Full record

ArticleSensors (Basel, Switzerland)2026

Array-Based CTD Thermal Sensing for Low-Flow Downhole Applications with Dual-Mode Compensation.

Zihan Lin, Yong Wei, Yifei Zhang, Ruyi Gan, Mei Wang, Qiang Chen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zihan LinSchool of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
Yong WeiSchool of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.ORCID 0000-0002-8520-2060
Yifei ZhangSchool of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.ORCID 0000-0002-8804-9778
Ruyi GanSchool of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
Mei WangSchool of Electronic Information and Electrical Engineering, Yangtze University, Jingzhou 434023, China.
Qiang ChenChina Petroleum Logging Co., Ltd., Xi'an 710077, China.

Funding

the CNPC Logging Co., Ltd. Technology Development Project 2025-1422the National Science and Technology Major Project of China 2025ZD1402103
6 · The paper itself

Abstract

Accurate downhole temperature sensing and low-flow characterization remain challenging in horizontal and highly deviated wells because of nonuniform cross-sectional flow, temperature drift, and probe-to-probe response differences. This study develops an array-based dual-mode constant-temperature-difference (CTD) sensing system for low-flow downhole applications. The system integrates one upstream temperature-sensing probe and six downstream heated sensing probes with pulse width modulation (PWM)-based CTD regulation, particle swarm optimization-genetic algorithm-proportional-integral-derivative (PSO-GA-PID) parameter tuning, probe-specific polynomial calibration, and depth-matched baseline compensation. The resulting framework is intended to improve the heating stability and consistency of the distributed thermal responses. Simulations using representative CTD thermal dynamics, together with repeated stochastic optimization, show that PSO refinement improves the repeatability of PID parameter tuning and reduces transient deviation. Experimental tests further show that PSO-GA-PID achieves a mean overshoot of 4.34% and a mean integral of time-weighted absolute error (ITAE) of 807.08, both lower than those of GA-PID. After polynomial calibration, the absolute temperature errors of all probes remain within ±0.6 °C over 10-60 °C and ±0.3 °C over 60-150 °C. Under single-phase water conditions, dual-mode baseline compensation reduces the maximum duty-cycle difference among the six sensing probes from 6.1-7.6 to 2.6-4.0 percentage points. The compensated heating duty cycle increases monotonically with flow rate and exhibits higher sensitivity over 0-30 m

Indexed as

constant-temperature-difference sensingdownhole loggingPSO–GA–PID controlsensor arraytemperature compensationthermal flow sensing

Identifiers

PMID42884333
PMCPMC13667551

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.