Evidence map›Paper›PMID 42884289›Full record

ReviewSensors (Basel, Switzerland)2026

Artificial Intelligence and Sensing Technologies for Vascular Access in Hemodialysis: A Narrative Review.

Concetto Sessa, Elettra Lomeo, Walter Morale, Tito Gianni, Bibiana Bonerba, Giuseppe Grandaliano, Francesco Pesce

Abstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Concetto SessaDepartment of Nephrology and Dialysis, Maggiore "Nino Baglieri" Hospital, 97015 Modica, Italy.ORCID 0000-0002-9144-0647
Elettra LomeoNephrology, Dialysis and Transplantation Unit, Department of Medical and Surgical Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy.ORCID 0009-0009-6808-3598
Walter MoraleDepartment of Nephrology and Dialysis, Maggiore "Nino Baglieri" Hospital, 97015 Modica, Italy.ORCID 0009-0003-3153-2042
Tito GianniDepartment of Nephrology, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, PA 19107, USA.ORCID 0009-0001-9927-8859
Bibiana BonerbaNephrology, Dialysis and Transplantation Unit, Department of Medical and Surgical Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy.
Giuseppe GrandalianoNephrology, Dialysis and Transplantation Unit, Department of Medical and Surgical Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy.
Francesco PesceDepartment of Translational Medicine and Surgery, Università Cattolica del Sacro Cuore, 00168 Rome, Italy.ORCID 0000-0002-2882-4226

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Vascular access performance determines the adequacy, safety, and cost of hemodialysis. Stenosis, thrombosis, cannulation difficulty, infection, and access-related cardiac stress remain major sources of morbidity. This narrative review examines artificial intelligence and sensing technologies for vascular access care, based on PubMed and ClinicalTrials.gov searches through 22 August 2026 with citation chaining. Existing reviews have examined artificial intelligence in dialysis broadly or prediction models in isolation. In this review, the vascular access itself is kept as the unit of analysis, and the evidence is followed across four connected stages: systemic risk stratification; prediction of maturation, dysfunction, and complications from clinical, ultrasound, and multimodal data; longitudinal monitoring with optical, acoustic, vibration, thermal, and pressure sensors; and procedural support with robotics and visualization technologies. Reported discrimination is high in retrospective, recording-level analyses, reaching areas under the curve of 0.99 and sample-level accuracy of 100%, but falls to approximately 0.71 in longitudinal designs that predict future events in the same patients; patient-level external validation and calibration are also rarely reported. No approach has yet been demonstrated to reduce thrombosis, prolong patency, avoid interventions, or lower cost relative to standard care in prospective multicenter studies. Deployment is further constrained by power budgets, duty cycling, and transmission bandwidth in wearable devices. Technical feasibility should not be read as clinical utility.

Indexed as

Artificial IntelligenceRenal DialysisVascular Access DevicesDigital HealthHumansMonitoring, PhysiologicWearable Electronic Devicesacoustic sensingarteriovenous fistulaartificial intelligenceedge computinghemodialysismachine learningvascular accesswearable sensors

Identifiers

PMID42884289
PMCPMC13667549

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked