A Wearable Morphic Sensor for Unobtrusive Heart Rate and Respiratory Rate Monitoring in ICU Patients: A Pilot Validation Study.

Titus Jayarathna, Caitlin Polley, Paul P Breen, Gaetano D Gargiulo, Anders Aneman

Abstract readValidation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Titus JayarathnaThe MARCS Institute for Brain, Behaviour and Development, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia.ORCID 0000-0002-1849-4235
Caitlin PolleySchool of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia.
Paul P BreenThe MARCS Institute for Brain, Behaviour and Development, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia.ORCID 0000-0002-8860-2086
Gaetano D GargiuloSchool of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia.ORCID 0000-0002-2616-2804
Anders AnemanDepartment of Intensive Care, Liverpool Hospital, Elizabeth Street, Liverpool, NSW 2170, Australia.ORCID 0000-0003-2096-5304

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis pilot study evaluated the real-world accuracy of a novel wearable morphic sensor system for unobtrusive, continuous heart rate (HR) and respiratory rate (RR) monitoring in critically ill patients within an intensive care unit (ICU).

methodsA hybrid piezoresistive/piezoelectric disk-shaped sensor was placed on patients' backs to capture cardiorespiratory activity via forcecardiographic principles. Data were acquired from 15 ICU patients using a custom wireless recorder. The piezoelectric channel was processed using discrete wavelet transform and an adaptive peak detection algorithm. Derived HR and RR were compared against reference measurements from clinical patient monitors and a ventilator.

resultsBland-Altman analysis showed a mean bias of -0.39 ± 1.99 beats per minute for HR and 0.06 ± 0.90 breaths per minute for RR. Linear regression revealed strong correlation with clinical monitors (HR R-squared = 0.982; RR R-squared = 0.966). The device's RR performance matched the agreement between two independent clinical reference devices.

conclusionThe proposed system met the pre-specified bias and standard deviation criteria for HR and RR monitoring in bed-bound ICU patients. Its skin-adhesive-free design enables unobtrusive, continuous vital sign surveillance without direct skin contact. These findings support ICU monitoring. Step-down ward and ambulatory applications remain to be validated in future studies.

Indexed as

Heart RateRespiratory RateWearable Electronic DevicesAgedAlgorithmsFemaleHumansIntensive Care UnitsMaleMiddle AgedMonitoring, PhysiologicPilot ProjectsSignal Processing, Computer-Assisteddiscrete wavelet transformforcecardiographic signalICU monitoringmorphic sensorsvital signswearable electronics

Identifiers

PMID42884252
PMCPMC13667736

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.