Evidence map›Paper›PMID 42882582›Full record

ArticleMaterials (Basel, Switzerland)2026

Structural Optimization and Fatigue Performance Evaluation of Balloon-Expandable Aortic Valve Stents.

Tao Cai, Chaoqun Zhao, Gang Fang

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Tao CaiDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
Chaoqun ZhaoDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, China.
Gang FangDepartment of Mechanical Engineering, Tsinghua University, Beijing 100084, China.ORCID 0000-0002-5409-3922

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transcatheter aortic valve implantation (TAVI) is a critical therapy for aortic stenosis, but most existing valve stents are designed for Western patients, whose aortic root anatomy differs from Chinese patients characterized by smaller annulus diameters, heavier calcification, and a higher prevalence of bicuspid valves. To address this mismatch, we designed a balloon-expandable aortic valve stent tailored for Chinese patients and systematically evaluated its performance. Four structural schemes were considered; a diamond-hexagonal composite mesh was selected based on radial strength, expansion uniformity, anchoring stability, sealing, and coronary access. Material properties of MP35N were obtained via tensile tests, and finite element models simulated crimping, recoil, and expansion. Among three end-corner geometries, the U-shaped design showed superior mechanical behavior with lower stress/strain concentrations. For stents crimped to 6.5 mm, maximum equivalent stress ranged from 1030 to 1076 MPa and plastic strain from 0.221 to 0.259; upon expansion to 20-29 mm, stress reached 1417-1493 MPa and strain 0.447-0.544, with strain concentrated at the corner ends. Simulated recoil matched experimental results within 7% relative error. Accelerated fatigue testing (4 × 10

Indexed as

aortic valve stentfinite element simulationin vitro bench teststructural design optimization

Identifiers

PMID42882582
PMCPMC13666492

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.