Evidence map›Paper›PMID 42882542›Full record

ArticleMaterials (Basel, Switzerland)2026

Progressive Changes in Commercial Orthopedic Drill Bits During Repeated Drilling of Synthetic Bone: Drill-Point Geometry, Thrust Force, Feed Work, and Hole Diameter.

Tomasz Bartkowiak, Mikołaj Nęcka, Marcin Pelic, Paweł Zawadzki, Dominika Podbereska, Stanisław Pabiszczak, Michał Jakubowicz, Jakub Czyżycki, Paweł Twardowski, Jakub Stefaniak and 2 more

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Tomasz BartkowiakInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.ORCID 0000-0002-4715-6358
Mikołaj NęckaInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.
Marcin PelicInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.ORCID 0000-0002-5076-8128
Paweł ZawadzkiInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.ORCID 0000-0001-8153-8774
Dominika PodbereskaInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.
Stanisław PabiszczakInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.
Michał JakubowiczInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.ORCID 0000-0002-6350-0411
Jakub CzyżyckiInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.ORCID 0000-0002-9870-1432
Paweł TwardowskiInstitute of Mechanical Technology, Poznan University of Technology, 61-131 Poznan, Poland.ORCID 0000-0002-1823-6279
Jakub StefaniakRehasport Clinic, 60-201 Poznan, Poland.ORCID 0000-0001-6849-3954
Maciej SzymankiewiczPoznan University of Medical Sciences Poznan, Adult Spine Orthopaedics Department, 61-545 Poznan, Poland.
Jakub GłowackiPoznan University of Medical Sciences, Department of Spine Disorders and Pediatric Orthopedics, 61-545 Poznan, Poland.ORCID 0000-0002-8200-742X

Funding

Ministry of Science and Higher Education SBAD/1603 and SBAD/1620
6 · The paper itself

Abstract

Repeated use can alter the geometry and functional performance of orthopedic drill bits, yet geometry, process load, and hole dimensions are rarely tracked together. Four integrated commercial drill types-Stryker (3.2 and 3.5 mm), Synthes (4.5 mm), and Zimmer (4.3 mm)-produced successive through-holes in a 6 mm short-glass-fiber-filled epoxy cortical-bone analog at 900 rpm and approximately 40 mm/min. Projected point angle was measured intermittently, maximum thrust force and axial feed work were calculated per hole, and entrance diameter was measured optically. The primary estimand was longitudinal change within each drill type; the design was not factorial, and differences among types cannot be attributed separately to manufacturer, diameter, geometry, intended function, or alloy. Drill-type-specific models included fixed specimen intercepts. Force, work, and diameter were described using constrained monotonic functions selected by AICc, while trend inference used permutation-based Spearman tests. Point angle decreased significantly only for the Stryker drills. Force and work increased in every type, whereas entrance diameter decreased significantly for Stryker 3.5 mm, Synthes, and Zimmer. Pairwise force/work-diameter associations did not remain significant after adjustment for hole number and multiplicity. Repeated-use exposure therefore produced drill-type-specific mechanical and dimensional drift, but the study did not directly quantify cutting-edge wear or establish a causal material mechanism.

Indexed as

axial feed workdrill conditionhole diameterorthopaedic drillingprojected point anglerepeated drill usesynthetic bonethrust force

Identifiers

PMID42882542
PMCPMC13665967

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.