Evidence map›Paper›PMID 42881172›Full record

ArticleNature communications2026

Symbiotic heat sharing in MOF-based atmospheric water generators for battery thermal management and sorbent regeneration.

Weicheng Chen, Mingyun Luo, Yuxuan Tan, Lintao Yan, TingTing Liao, Weiqi Liu, Fengwen Liu, Zhixuan Chen, Jinze Yao, Xianghui Liang and 7 more

Abstract read
In one paragraph

Article in Nature communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Weicheng ChenSchool of Energy and Environment, City University of Hong Kong, Hong Kong, China.
Mingyun LuoKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Yuxuan TanKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Lintao YanKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
TingTing LiaoKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Weiqi LiuKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Fengwen LiuKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Zhixuan ChenKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Jinze YaoKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Xianghui LiangKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.
Yutang FangKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.ORCID http://orcid.org/0000-0002-2804-9178
Shuangfeng WangKey Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou, China.ORCID http://orcid.org/0009-0008-6723-1053
Yujie KeWu Jieh Yee School of Interdisciplinary Studies, Lingnan University, Hong Kong, China.
Ady SuwardiDepartment of Electronic Engineering, and Shun Hing Institute of Advanced Engineering, The Chinese University of Hong Kong, Sha Tin, Hong Kong SAR, Hong Kong.ORCID http://orcid.org/0000-0002-7342-0431
Anthony Chun Yin YuenDepartment of Building Environment and Energy Engineering, The Hong Kong Polytechnic University, Hong Kong, China. anthony-cy.yuen@polyu.edu.hk.ORCID http://orcid.org/0000-0002-1433-447X
Swee Ching TanDepartment of Materials Science and Engineering, National University of Singapore, Singapore, Singapore. msetansc@nus.edu.sg.ORCID http://orcid.org/0000-0003-2074-8385
Sai Kishore RaviSchool of Energy and Environment, City University of Hong Kong, Hong Kong, China. skravi@cityu.edu.hk.ORCID http://orcid.org/0000-0002-9785-3215

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Atmospheric water harvesting (AWH) is limited by the high energy demand for sorbent regeneration, while battery thermal management dissipates substantial low-grade heat unused. Here, we propose a thermally symbiotic architecture integrating these systems. Battery discharge waste heat regenerates a MOF-303 sorbent layer via desorption, while the sorption process passively stabilizes battery temperature. The sorbent's regeneration enthalpy aligns with the battery's thermal output, triggering desorption under -12 to -20 A discharge. Within 46 min, the MOF exceeds 50 °C, releasing vapor for condensation in a sealed setup. Concurrently, sorption extracts heat from the battery, reducing peak temperatures by ~10 °C. Notably, this integrated system achieves a water production rate of 1.39 g g

Identifiers

PMID42881172
PMCPMC13672300

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.