Evidence map›Paper›PMID 42879507›Full record

ArticlePloS one2026

Evaluation of a novel body temperature sensor (CORE) in dogs under general anesthesia following premedication with dexmedetomidine or acepromazine: A pilot study.

Chloe R Dupleix, Jacob P Rastas, Qianqian Zhao, Robert Young, Rebecca A Johnson

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chloe R DupleixDepartment of Surgical Sciences, University of Wisconsin, Madison, Wisconsin, United States of America.
Jacob P RastasDepartment of Surgical Sciences, University of Wisconsin, Madison, Wisconsin, United States of America.ORCID https://orcid.org/0000-0003-3049-7874
Qianqian ZhaoDepartment of Biostatistics and Medical Informatics, University of Wisconsin, Madison, Wisconsin, United States of America.
Robert YoungWaldoPet, Waukesha, Wisconsin, United States of America.
Rebecca A JohnsonDepartment of Surgical Sciences, University of Wisconsin, Madison, Wisconsin, United States of America.ORCID https://orcid.org/0000-0003-4031-1762

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Core body temperature monitoring in anesthetized dogs is a vital part of physiological evaluation. Depending on the procedure and patient positioning, consistent core temperature measurements can be difficult to obtain. The objective of this study was to evaluate the reliability and clinical validity of a wireless, non-invasive, superficial heat flux-based thermometric device (CORE, greenTEG AG, Rümlang, Switzerland). Three healthy beagle dogs were premedicated with either dexmedetomidine or acepromazine prior to induction with intravenous propofol and isoflurane maintenance. They were monitored every five minutes with pulse oximetry, non-invasive blood pressure, electrocardiography, and capnometry. Rectal thermometry and temperatures from the CORE sensor placed on clipped and unclipped skin over the jugular veins were measured every three minutes for up to 120 minutes following induction. Based on the correlation coefficient for repeated measures (rrm) and the Shrout-Fleiss intraclass correlation coefficient (ICC), in dogs administered acepromazine, there was good, statistically significant correlation and reliability between rectal and clipped CORE temperatures (rrm = 0.81, P < 0.0001; ICC = 0.78) and rectal and unclipped CORE temperatures (rrm = 0.79, P < 0.0001; ICC = 0.85). In dogs administered dexmedetomidine, although values were correlated (rrm = 0.30, P < 0.0001), there was poor reliability (ICC = 0.28) between rectal and clipped CORE temperatures which improved if dogs were unclipped (rrm = 0.48, P < 0.0001; ICC = 0.88). Clinically acceptable Bland-Altman agreements were found between rectal and unclipped CORE methods. These preliminary results suggest that the CORE sensor may provide an alternative method for assessing core body temperatures in unclipped, anesthetized dogs.

Indexed as

AcepromazineAnesthesia, GeneralBody TemperatureDexmedetomidinePremedicationThermometryAnimalsDogsFemaleMaleMonitoring, PhysiologicPilot ProjectsReproducibility of ResultsAcepromazineDexmedetomidine

Identifiers

PMID42879507
PMCPMC13671644

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.