Evidence map›Paper›PMID 42878918›Full record

ArticleHernia : the journal of hernias and abdominal wall surgery2026

Macroscopic, radiologic, and microscopic analysis of explanted abdominal wall prosthesis.

Léna Christ, Benoit Romain, Guillaume Philouze, Nicole Neumann, Anne Lejay, Juliette Tabouret, Nabil Chakfé

Abstract read
PubMed Publisher
In one paragraph

Article in Hernia : the journal of hernias and abdominal wall surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Léna ChristGEPROMED, 4 Rue Kirschleger, Strasbourg, 67000, France.
Benoit RomainDepartment of Digestive Surgery, University Hospital of Strasbourg, Strasbourg, France.
Guillaume PhilouzeDepartment of Digestive Surgery, University Hospital of Strasbourg, Strasbourg, France.
Nicole NeumannGEPROMED, 4 Rue Kirschleger, Strasbourg, 67000, France.
Anne LejayGEPROMED, 4 Rue Kirschleger, Strasbourg, 67000, France.
Juliette TabouretGEPROMED, 4 Rue Kirschleger, Strasbourg, 67000, France. explant@gepromed.com.
Nabil ChakféGEPROMED, 4 Rue Kirschleger, Strasbourg, 67000, France.

Funding

Conseil régional du Grand Est Conseil régional du Grand EstEurométropole de Strasbourg Eurométropole de StrasbourgEuropean Regional Development Fund European Regional Development Fund
6 · The paper itself

Abstract

purposeCharacterize the textile structure, degradation patterns, and calcification of explanted parietal reinforcement implants (PRI), in order to better understand potential mechanisms contributing to mesh-related complications.

methodsA multimodal analytical approach combining macroscopic examination, high-resolution radiographic imaging and microscopic analysis was performed before and after removal of surrounding biological tissues on explanted PRI.

resultsTwenty-two explanted PRI were analyzed, including five biosynthetic meshes and seventeen fully synthetic non-resorbable meshes. Mean implantation duration was 41 months (range, [0-220]). Indications for explantation were hernia recurrence (n = 14, 64%), mesh infection (n = 4, 18%), unrelated surgery (n = 3, 14%), and bowel obstruction (n = 1, 4%). Macroscopic analysis showed encapsulation within biological tissues (n = 16), rigidity (n = 6), and fragmentation (n = 3), sometimes combined. Radiographic imaging revealed suggestive calcifications in four explants, and suggestive fibrosis and/or milder mineralized deposits in twelve. Nineteen non-resorbable meshes underwent digital optical microscopy after enzymatic cleaning (2 explants each contained 2 devices). Textile structures included warp-knitted meshes (n = 16), weft-knitting mesh (n = 1), and nonwoven materials (n = 2); six devices also incorporated a plastic membrane. Monofilament yarns predominated (n = 15) whereas multifilament yarns (n = 4) showed signs of fibrillation. Fixation systems included staples (n = 3) and suture threads (n = 6). Structural abnormalities included holes (n = 7), clean cuts (n = 7), tearing (n = 1), and forceps marks (n = 3), variably attributable to surgical/handling artefacts or pre-existing degradation, though this could not be established with certainty.

conclusionThis pilot study demonstrates the feasibility of a multimodal approach for characterizing explanted PRI. Larger studies are needed to clarify mesh failure mechanisms and thereby optimize implant selection and surgical use.

Indexed as

Abdominal WallHerniorrhaphySurgical MeshCalcinosisDevice RemovalHardware RemovalHumansDegradationExplant analysisMeshParietal reinforcement implantsRadiography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.