Evidence map›Paper›PMID 42878917›Full record

ArticleInternational ophthalmology2026

Comparative safety and complication profiles of two three-piece intraocular lenses in Yamane technique.

Erdi Karadağ, Güzide Akçay, Burak Tanyıldız, Ulviye Kıvrak, Esengül Kuş Solmaz

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Erdi KaradağDepartment of Ophthalmology, Kartal Doctor Lutfi Kirdar City Hospital, University of Health Sciences, D-100 South Side Road No:47, Cevizli, 34865, Istanbul, Turkey. erdi_karadag@hotmail.com.ORCID https://orcid.org/0000-0002-4168-8740
Güzide AkçayDepartment of Ophthalmology, Kartal Doctor Lutfi Kirdar City Hospital, University of Health Sciences, D-100 South Side Road No:47, Cevizli, 34865, Istanbul, Turkey.ORCID http://orcid.org/0000-0002-6111-9772
Burak TanyıldızDepartment of Ophthalmology, Acıbadem Kartal Hospital, 34873, Istanbul, Turkey.ORCID http://orcid.org/0000-0001-8245-8389
Ulviye KıvrakDepartment of Ophthalmology, Kartal Doctor Lutfi Kirdar City Hospital, University of Health Sciences, D-100 South Side Road No:47, Cevizli, 34865, Istanbul, Turkey.ORCID http://orcid.org/0000-0003-1694-6864
Esengül Kuş SolmazDepartment of Ophthalmology, Kartal Doctor Lutfi Kirdar City Hospital, University of Health Sciences, D-100 South Side Road No:47, Cevizli, 34865, Istanbul, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare the mechanical behavior, intraoperative events, and postoperative outcomes of two three-piece intraocular lenses (IOLs) with different haptic materials-polymethyl methacrylate (PMMA) and polyvinylidene fluoride (PVDF)-implanted using the Yamane fixation technique.

methodsThis retrospective comparative study included eyes undergoing Yamane scleral fixation with either a PMMA-haptic IOL (Alcon MA60AC) or a PVDF-haptic IOL (Eyecryl Plus TP613). Preoperative and postoperative month 6 best-corrected visual acuity (BCVA), intraocular pressure (IOP), and cylindrical refraction, as well as intraoperative haptic-related complications including haptic tip breakage and optic-haptic junction separation, postoperative IOL dislocation, and other postoperative complications were recorded and analyzed.

resultsSeventy-four eyes (37 per group) were included. Baseline demographic and preoperative clinical characteristics were similar between groups. At 6 months, BCVA improved significantly in both groups without a significant intergroup difference, and postoperative IOP values and cylindrical refraction were comparable. Intraoperative complications were more frequent in the Alcon group (32.4%, 95% CI 19.6-48.5% vs. 5.4%, 95% CI 1.5-17.7%; p = 0.003), with haptic-related complications occurring exclusively in this group. Overall postoperative complication rates were similar; however, IOL dislocation occurred only in the Alcon group (16.2%, 95% CI 7.7-31.1% vs. 0%; p = 0.025). Other postoperative complications did not differ significantly.

conclusionBoth IOLs yielded comparable improvements in visual acuity; however, all haptic-related complications and IOL dislocations occurred exclusively in the Alcon MA60AC group. These findings suggest that IOL selection is an important consideration in Yamane fixation, and the Eyecryl Plus TP613 with its PVDF haptics and more favorable design profile may offer greater biomechanical reliability.

Indexed as

Intraoperative ComplicationsLenses, IntraocularLens Implantation, IntraocularPostoperative ComplicationsRefraction, OcularVisual AcuityAgedFemaleFluorocarbon PolymersFollow-Up StudiesHumansMaleMiddle AgedPolymethyl MethacrylatePolyvinylsProsthesis DesignFluorocarbon PolymersPolymethyl Methacrylatepolyvinylidene fluoridePolyvinylsHapticIntraocular lensPolymethyl methacrylate (PMMA) materialPolyvinylidene fluoride (PVDF) materialYamane technique

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked