Evidence map›Paper›PMID 42878899›Full record

ArticleClinical oral investigations2026

Static and fatigue behavior of one- and two-piece zirconia implant abutment systems: an in vitro study.

Pedro Diaz, Monica Lopez, Luis J Gil Villagra, Juan Carlos Del Real, Seyed Ali Mosaddad, Maria J Suarez

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Pedro DiazDepartment of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid (UCM), Plaza Ramón y Cajal s/n, Madrid, 28040, Spain.
Monica LopezDepartment of Clinic Grade Dentistry, Faculty of Odontology, European University of Madrid, Madrid, Spain.
Luis J Gil VillagraDepartment of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid (UCM), Plaza Ramón y Cajal s/n, Madrid, 28040, Spain.
Juan Carlos Del RealInstitute for Research in Technology/Mechanical Engineering Department, ICAI School of Engineering, Universidad Pontificia Comillas, Madrid, Spain.
Seyed Ali MosaddadDepartment of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid (UCM), Plaza Ramón y Cajal s/n, Madrid, 28040, Spain. semosadd@ucm.es.
Maria J SuarezDepartment of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid (UCM), Plaza Ramón y Cajal s/n, Madrid, 28040, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare static fracture behavior, fatigue survival, and fracture patterns of three one- and two-piece zirconia implant abutment systems. MATERIALS AND

methodsThree groups comprised 48 assemblies each: (1) Astra Tech ZirDesign, one-piece zirconia; (2) Biomet 3i CAP454, two-piece zirconia with a titanium base; and (3) Straumann RC Anatomic, one-piece zirconia. Within each group, 12 assemblies underwent initial static testing and 12 each underwent fatigue at 25%, 50%, or 75% of the system-specific reference load (10 Hz, approximately 30°, five million cycles). Static outcomes underwent one-way and Welch analyses of variance; pooled run-out proportions underwent exact tests (α = 0.05).

resultsMean static fracture loads were 1058 ± 225 N (Astra Tech), 866 ± 189 N (Biomet 3i), and 873 ± 402 N (Straumann), without a significant difference (p = .194). Calculated tensile-side stress differed (p = .016); compressive-side findings were method-dependent. Run-out was 88.9% at 25% (32/36; 95% confidence interval, 73.9%-96.9%) and 0% at higher levels (p < .001). Residual fracture outcomes described survivors only. Fractography indicated brittle cervical failure.

conclusionsStatic fracture-load superiority was not demonstrated. Fatigue run-out varied with relative loading; modeled stress differences do not establish intrinsic material-strength differences. CLINICAL RELEVANCE: These system-specific laboratory results cannot isolate an independent titanium-base effect or establish clinical service life.

Indexed as

Dental AbutmentsDental Implant-Abutment DesignDental MaterialsZirconiumDental Restoration FailureDental Stress AnalysisIn Vitro TechniquesMaterials TestingStress, MechanicalSurface PropertiesTitaniumDental MaterialsTitaniumZirconiumzirconium oxideCeramicsDental abutmentsDental implant-abutment designDental stress analysisMaterials testing

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.