Evidence map›Paper›PMID 42877843›Full record

ArticleIEEE journal of translational engineering in health and medicine2026

Evaluation of a Wrist-Worn Device for ECG-Based Detection of Acute Myocardial Infarction.

Karolina Eitminaviciene, Daivaras Sokas, Zygimantas Abramikas, Dziugile Kersnauskaite, Dominika Sirviene, Artiomas Sirvys, Guoste Stankeviciute, Vytautas Juknevicius, Justinas Bacevicius, Leif Sornmo and 1 more

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Karolina EitminavicieneBiomedical Engineering InstituteKaunas University of Technology Kaunas 44249 Lithuania.ORCID https://orcid.org/0009-0003-5557-1329
Daivaras SokasBiomedical Engineering InstituteKaunas University of Technology Kaunas 44249 Lithuania.ORCID https://orcid.org/0000-0001-5723-3655
Zygimantas AbramikasInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.ORCID https://orcid.org/0000-0003-3579-7913
Dziugile KersnauskaiteInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.
Dominika SirvieneInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.
Artiomas SirvysInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.
Guoste StankeviciuteInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.
Vytautas JukneviciusInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.ORCID https://orcid.org/0000-0001-9126-8560
Justinas BaceviciusInstitute of Clinical Medicine, Faculty of MedicineVilnius University Vilnius 01513 Lithuania.
Leif SornmoDepartment of Biomedical EngineeringLund University Lund 221 00 Sweden.ORCID https://orcid.org/0000-0001-8524-2292
Andrius PetrenasBiomedical Engineering InstituteKaunas University of Technology Kaunas 44249 Lithuania.ORCID https://orcid.org/0000-0002-5700-7196

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine whether a two-lead ECG (wECG), acquired using a self-applicable, wrist-worn device, provides diagnostic value in acute myocardial infarction (AMI) detection.

methodsSeventy-one patients with AMI, 26 with other cardiovascular diseases (CVDs), and 54 healthy controls were enrolled in the study. To acquire lead I, one electrode of the wrist-worn device was touched with the index finger of the opposite hand, while another lead was acquired by touching the electrode on the strap to a specific part of the body. The diagnostic value of the wECG is evaluated either directly or through synthesis of the standard 12-lead ECG using an echo state network.

resultsUsing the standard ECG, an AMI detector based on a convolutional neural network yields a sensitivity of 0.86 and a specificity of 0.71; the corresponding figures for blinded cardiologist diagnosis are 0.77/0.88. Using the synthesized ECG, the V3 electrode touch site yields the best performance, with a sensitivity/specificity of 0.84/0.71 for AMI detection and 0.67/0.86 for cardiologist diagnosis. Compared to the synthesized ECG across all touch sites, use of the wECG results in a substantially lower sensitivity, reduced by 0.12-0.13, while the specificity is comparable or slightly higher. Implementation of a two-stage approach, consisting of detector-based screening followed by cardiologist review of positive cases, results in correct decisions in 63% of the AMI cases using either the synthesized ECG or the wECG.

conclusionThe two-lead ECG acquired with a wrist-worn device offers diagnostic value and enables screening for AMI.

Indexed as

ElectrocardiographyMyocardial InfarctionSignal Processing, Computer-AssistedWearable Electronic DevicesAdultAgedFemaleHumansMaleMiddle AgedSensitivity and SpecificityWristconvolutional neural networkecho state networkindividual-specific modelscreeningWearable device

Identifiers

PMID42877843
PMCPMC13667300

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.