Evidence map›Paper›PMID 42877576›Full record

ArticleJournal of orthopaedic translation2026

Preclinical evaluation of a fully threaded biodegradable magnesium alloy headless compression screw for enhanced fixation in small bones.

Hiroshi Noguchi, Kotaro Hanada, Ryunosuke Watanabe, Yasukazu Totoki, Yohei Tomaru, Akira Ikumi, Akira Kitagawa, Sakiko Orui, Lulu Zhang, Hajime Mishima

Abstract read
In one paragraph

Article in Journal of orthopaedic translation, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hiroshi NoguchiDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan.
Kotaro HanadaIntegrated Research Center for Advanced Manufacturing, National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, 305-8564, Japan.
Ryunosuke WatanabeDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan.
Yasukazu TotokiDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan.
Yohei TomaruDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan.
Akira IkumiDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan.
Akira KitagawaMel-frontier Ltd., Tokyo, 170-0013, Japan.
Sakiko OruiMel-frontier Ltd., Tokyo, 170-0013, Japan.
Lulu ZhangNational Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, 305-8565, Japan.
Hajime MishimaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Ibaraki, 305-8575, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Biodegradable magnesium (Mg) alloys have attracted attention as alternatives to conventional metallic implants; however, their clinical applicability to fully threaded headless compression (HC) screws has been scarcely investigated. Methods: In this study, a fully threaded biodegradable Mg alloy HC screw was developed, and its mechanical performance, biological safety, and in vivo degradation behavior were systematically evaluated. Mechanical properties were assessed according to ASTM standards and compared with clinically used titanium (Ti) alloy and poly-L-lactic acid/hydroxyapatite (PLLA/HA) screws. Biological safety was evaluated in accordance with ISO 10993 and in compliance with Good Laboratory Practice. In vivo degradation behavior was investigated using a rabbit distal femoral condyle model. Results: The Mg alloy HC screw demonstrated superior torsional strength compared with PLLA/HA screws and comparable insertion performance, along with enhanced fixation strength, compared with Ti alloy screws. No cytotoxicity, sensitization, or intracutaneous reactivity was observed. Although transient gas cavity formation was observed during the early implantation period, it progressively diminished over time and did not adversely affect bone formation or implant stability. Conclusion: These findings indicate that the developed Mg alloy HC screw exhibits favorable mechanical performance, biocompatibility, and in vivo degradation. This study provides preclinical evidence supporting its potential clinical translation, particularly in eliminating the need for secondary implant removal surgery. The translational potential of this article: This article focuses on the preclinical evaluation of a fully threaded Mg-alloy HC screw developed to improve fixation performance for small bone fractures. The results of this study have significant clinical potential for the fully threaded design of biodegradable Mg alloy implants in fracture treatment.

Indexed as

Biodegradable magnesium alloyBiological safetyFully threaded compression screwHistological evaluationIn vivoMechanical performance

Identifiers

PMID42877576
PMCPMC13662688

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.