Geometric accuracy of applicator and needle reconstruction in gynecological brachytherapy using low-field magnetic resonance imaging.
Article in Journal of contemporary brachytherapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To evaluate the geometric accuracy of applicator reconstruction in gynecological brachytherapy using low-field magnetic resonance imaging. Material and methods: A 0.55T magnetic resonance (MR) scanner was used in this study. First, accuracy of needle reconstruction based on MR and computed tomography (CT) images were compared. Seven plastic needles were inserted into three phantoms, which were scanned with MR and CT. Five observers determined tip and entry points of the needles on both types of images. Needle lengths and tip coordinates were compared. Then, inter-observer variation in localization of applicator and needle tips in patients was evaluated on MR images. Twenty fractions of eleven patients treated with Venezia applicator with needles were selected. In tandem and ovoid tubes, MR markers were inserted, with only air in the needles. Differences between observers in determining the coordinates were depicted using standard deviation (SD). Results: The mean difference between needle depths was 1.16 ±0.8 mm measured on MR and CT images. Uncertainties among observers in determining the position of tips were generally small, with SD of less than 1.0 mm for both imaging modalities. A good correlation ( Conclusions: The 0.55T MR scanner can provide clinically acceptable accuracy in the reconstruction of brachytherapy (BT) applicators and needles. MR markers allow greater precision in determining the tips of applicators. The accuracy of reconstruction using MR images is comparable to that achieved with CT images.